BCR30AM-12LB_15 Datasheet, PDF (1/10 Pages) Renesas Technology Corp – Triac Medium Power Use (The product guaranteed maximum junction temperature of 150C)
BCR30AM-12LB
Triac
Medium Power Use
(The product guaranteed maximum junction temperature of 150°C)
Features
• IT(RMS) : 30 A
• VDRM : 600 V
• IFGT I, IRGT I, IRGT III : 50 mA
Outline
• Non-Insulated Type
• Planar Passivation Type
REJ03G0472-0300
Rev.3.00
Nov 30, 2007
RENESAS Package code: PRSS0004ZE-A
(Package name: TO-3P)
4
2, 4
12 3
3
1
1. T1 Terminal
2. T2 Terminal
3. Gate Terminal
4. T2 Terminal
Applications
Contactless AC switch, electric heater control, light dimmer, on/off and speed control of small induction motor, on/off
control of copier lamp
Warning
1. Refer to the recommended circuit values around the triac before using.
2. Be sure to exchange the specification before using. Otherwise, general triacs with the maximum
junction temperature of 125°C will be supplied.
Maximum Ratings
Parameter
Repetitive peak off-state voltageNote1
Non-repetitive peak off-state voltageNote1
Symbol
VDRM
VDSM
Voltage class
12
600
720
Unit
V
V
REJ03G0472-0300 Rev.3.00 Nov 30, 2007