English
Language : 

T4810117 Datasheet, PDF (8/8 Pages) Red Lion Controls. Inc – MODEL T48 - 1/16 DIN TEMPERATURE CONTROLLER
ORDERING INFORMATION
Options and Output Boards are factory configured per the part number specified. Part numbers without
replacement output boards listed must be returned to the factory for output board replacement.
MODELS WITHOUT RS485 AND LINEAR DC ANALOG OUTPUT
DEDICATED
MAIN CONTROL
01 OUTPUT
DEDICATED
ALARM 1
A1 OUTPUT
(ALARM 2)
A2 OR 02
(COOL)*
REMOTE
SETPOINT
INPUT @
HEATER
CURRENT
INPUT @
Relay
Relay
Relay
Relay
Relay
Relay
Relay
Relay
Relay
YES
Relay
Relay
Relay
YES
Logic/SSR
Logic/SSR
Relay
Logic/SSR
Relay
Relay
Logic/SSR
Relay
Relay
YES
Logic/SSR
Relay
Relay
YES
Triac
Logic/SSR
Logic/SSR
* - This output is programmable as either Control (PID) or as an Alarm.
@ - These part numbers are equipped with a second setpoint.
REPLACEMENT
OUTPUT
BOARD
RBD48100
RBD48111
RBD48111
RBD48111
RBD48111
RBD48200
RBD48211
RBD48211
RBD48211
RBD48211
NA
PART NUMBERS
18-36 VDC/24 VAC 85 TO 250 VAC
T4810010
NA
T4811110
T4811113
T4811114
T4820010
NA
T4821110
T4821113
T4821114
T4832210
T4810000
T4811000
T4811100
T4811103
T4811104
T4820000
T4821000
T4821100
T4821103
T4821104
T4832200
Option Boards are installed at the factory for the appropriate models. These boards are only needed for field replacement.
MODELS WITH RS485 OR LINEAR DC ANALOG OUTPUT
DEDICATED MAIN CONTROL
MAIN CONTROL
O1 OR A1
O1 OUTPUT
(ALARM 1) *
DEDICATED
ALARM 1
A1 OUTPUT
(ALARM 2)
A2 OR O2
(COOL) *
REMOTE
SETPOINT
INPUT @
HEATER
CURRENT
INPUT @
RS485
@
Relay
YES 1
Relay
Relay
Relay
Relay
Relay
Relay
YES
Relay
Relay
YES
Relay
Relay
YES
Relay
Relay
YES
YES
Relay
Relay
YES
YES
Relay
Relay
Relay
YES 2
Logic/SSR
Logic/SSR
Logic/SSR
Logic/SSR
YES
Logic/SSR
Logic/SSR
YES
Logic/SSR
Logic/SSR
YES
YES
Logic/SSR
Logic/SSR
YES
YES
Logic/SSR
Relay
Relay
YES
* - This output is programmable as either Control (PID) or as an Alarm.
** - This output is jumper and program selectable for either a current or voltage Linear DC output.
@ - These part numbers are equipped with a second setpoint.
1 - Replacement Output Board RBD48100 may be used.
2 - Replacement Output Board RBD48111 may be used.
MAIN
SECOND
PART NUMBERS
ANALOG
ANALOG
OUTPUT** @ OUTPUT** @ 18-36 VDC/24 VAC 85 TO 250 VAC
NA
T4810002
YES
YES
T481011A
T481010A
YES
T4810111
T4810101
YES
T4810115
T4810105
YES
T4810116
T4810106
YES
T4810117
T4810107
T4810118
T4810108
T4810119
T4810109
T4811112
T4811102
YES
T4820211
T4820201
YES
T4820215
T4820205
YES
T4820216
T4820206
T4820218
T4820208
T4820219
T4820209
T4821112
T4821102
ACCESSORIES
MODEL NO. DESCRIPTION
External SSR Power Unit (for Logic/SSR output models)
Single Phase 25 A DIN Rail Mount SSR
RLY
Single Phase 40 A DIN Rail Mount SSR
Three Phase DIN Rail Mount SSR
40 Ampere Current Transformer (for Heater Current Input models)
CT
50 Ampere Current Transformer (for Heater Current Input models)
SFCRM Crimson 2 PC Configuration Software for Windows 98, ME, 2000 and XP (for RS485 models)
ICM4 RS232/RS485 Serial Converter Module
ICM5 Three way isolated RS232/RS485 Serial Converter
* Crimson software is available for download from http://www.redlion.net
Red Lion Controls
Headquarters
20 Willow Springs Circle
York PA 17406
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
Red Lion Controls
Europe
Softwareweg 9
NL - 3821 BN Amersfoort
Tel +31 (0) 334 723 225
Fax +31 (0) 334 893 793
Red Lion Controls
India
201-B, 2nd Floor, Park Centra
Opp 32 Mile Stone, Sector-30
Gurgaon-122002 Haryana, India
Tel +91 984 487 0503
PART NUMBERS
RLY50000
RLY60000
RLY6A000
RLY70000
CT004001
CT005001
SFCRM
ICM40030
ICM50000
Red Lion Controls
China
Unit 302, XinAn Plaza
Building 13, No.99 Tianzhou Road
ShangHai, P.R. China 200223
Tel +86 21 6113 3688
Fax +86 21 6113 3683