English
Language : 

PXU100B0 Datasheet, PDF (25/32 Pages) Red Lion Controls. Inc – MODEL PXU - TEMPERATURE/PROCESS CONTROLLERS
PARAMETER VALUE CHART
Programmer:______________________Date:_________
Controller Number:_______ Security Code:_______
INPUT MODULE ( )
DISPLAY
typE
SCAL
dCPt
FLtr
bANd
SHFt
dSP1
dSP2
SPLO
SPHI
CJC
USr1
USr2
F1In
F2In
PARAMETER
Input Type
Temperature Scale
Decimal Resolution
Digital Filtering
Input Filter Band
Shift/Offset
Display Value Scaling Point 1
Display Value Scaling Point 2
Setpoint Low Limit
Setpoint High Limit
Cold Juction Compensation
User1 Function
User2 Function
F1 Key Function
F2 Key Function
OUTPUT MODULE (2-OP)
DISPLAY
OPAC
CtrL
CYC1
OP1L
OP1H
IF01
An1L
An1H
CYC2
OP2L
OP2H
IF02
gAN2
db-2
CHYS
PARAMETER
Control Action
Auto Control Mode
OP1 Cycle Time
OP 1 Power Low Limit
OP 1 Power High Limit
Input Fail OP1 Power Level
Analog Low
Analog High
OP2 Cycle Time
OP 2 Power Low Limit
OP 2 Power High Limit
Input Fail OP2 Power Level
Relative Gain
Deadband/Overlap
On/Off Control Hysteresis
LOCKOUT MODULE ()
DISPLAY
SP
OP1
OP2
SPrP
PId
r-S
OPOF
ProP
Intt
dErt
dInt
AL-1
AL-2
AL-3
ALrS
SPSL
tUNE
CtrL
trnf
dEv
CodE
PARAMETER
Setpoint
Output 1 Power
Output 2 Power
Setpoint Ramp Rate
PID Group
Controller Status
Output Power Offset
Proportional Band
Integral Time
Derivative Time
Integration Default
Alarm 1 Value
Alarm 2 Value
Alarm 3 Value
Alarm Reset
Setpoint Select
Auto-Tune Code
Auto Control Mode
Control Mode Transfer
Deviation Value
Access Code
FACTORY
SETTING
tc-J
°F
0
8
1
0
0
1000
-148
2192
On
NONE
NONE
NONE
NONE
USER SETTING
FACTORY
SETTING
r1r2
PId
2.0
0.0
100.0
0.0
0.0
100.0
2.0
0.0
100.0
0.0
1.00
2
2
USER SETTING
FACTORY
SETTING
dISP
PArA
PArA
PArA
PArA
dISP
PArA
PArA
PArA
PArA
LOC
PArA
PArA
PArA
PArA
PArA
HIdE
HIdE
HIdE
dISP
0
USER SETTING
ALARM MODULE ()
DISPLAY
ACt1
Lit1
rSt1
Stb1
AL-1
IFA1
ACt2
Lit2
rSt2
Stb2
AL-2
IFA2
ACt3
Lit3
rSt3
Stb3
AL-3
IFA3
AHYS
Colr
PARAMETER
Alarm 1 Action
Alarm 1 Annunciator
Alarm 1 Reset Mode
Alarm 1 Standby
Alarm 1 Value
Alarm 1 Input Fail Action
Alarm 2 Action
Alarm 2 Annunciator
Alarm 2 Reset Mode
Alarm 2 Standby
Alarm 2 Value
Alarm 2 Input Fail Action
Alarm 3 Action
Alarm 3 Annunciator
Alarm 3 Reset
Alarm 3 Standby
Alarm 3 Value
Alarm 3 Input Fail Action
Alarm Hysteresis
Change Display Color
FACTORY
SETTING
NONE
nor
Auto
NO
100
OFF
NONE
nor
Auto
NO
200
OFF
NONE
nor
Auto
NO
300
OFF
1
OFF
USER SETTING
SERIAL COMMUNICATIONS MODULE (7-SC)
DISPLAY
tYPE
bAUd
dAtA
PArb
Addr
PARAMETER
Communications Type
Baud Rate
Data Bit
Parity Bit
Unit Address
FACTORY
SETTING
rtV
38K4
8
NO
247
USER SETTING
25