English
Language : 

ZCH0100C Datasheet, PDF (2/4 Pages) Red Lion Controls. Inc – MODEL ZCH - QUADRATURE OUTPUT ROTARY PULSE GENERATOR
ZFH DIMENSIONS In inches (mm)
This is the side view of the Model
ZFH. All other dimensions (including
the handle tube) are the same as
the Model ZGH. See below.
1.20
(30.5)
0.04
(1.0)
0.75
(19.0)
1.65
(41.9)
0.08 (2.03)
MAX.
ZGH DIMENSIONS In inches (mm)
2.75 (69.9)
3.38
(85.8)
2.00
(50.8)
.04
(1.0)
4.00 (101.6)
1.65 (41.9)
.08
(2.03)
MAX.
.75
(19.0)
TYP. 2
USABLE SHAFT
LENGTH
1.08 (27.4)
REF., TYP. 2
.022 (.56)
TYP. 2
0.375 (9.52)
DIA. SHAFT
.13 (3.3)
2.06
(52.3)
2.00 (50.8) DIA.
2.75
(69.8)
.75 (19) DIA.
EQUIVALENT CIRCUIT & CONNECTIONS
LED
REGU-
LATOR
RED
8-28VDC @ 30mA
(TYP.) 50mA MAX.
METAL
ETCHED
OPTICAL
DISC
SENSOR
ARRAY
WHT
GRN
BLK
BARE STRANDED SHIELD WIRE
CONNECTED TO INSTRUMENT
COMMON FOR INCREASED
NOISE IMMUNITY
CHANNEL A
CHANNEL B
VOH = 30VDC MAX.
VOL = 1V MAX. @ 40mA
COMMON
(NOTE 4)
1 CYCLE (360°)
"a"
"b"
"c"
(NOTE 2)
(NOTE 3)
CHAN. A
CHAN. B
C.C.W.
C.W.
SHAFT ROTATION
(NOTE 1)
VOL
VOH
COMMON
VOH
COMMON
VOL
NOTES:
1. Channel A leads Channel B for clockwise shaft rotation when viewed from
housing front. Conversely, Channel B leads Channel A for Counterclockwise
shaft rotation.
2. The number of lines on the optical disc determines the Pulses Per Revolution
(PPR).
3. Duty Cycle is the relationship of output “High” time, “a”, to output “Low”
time, “b”, and is expressed as a High/Low percentage ratio, ie....% High time
= a/(a+b) x 100; % Low time = b/(a+b) x 100.
4. Quadrature Phase “c” is specified as the lead or lag between Channel A & B
in electrical degrees. Nominally 90° (1/4 cycle).
LENGTH SENSOR MOUNTING CONSIDERATION
1. Length Sensors should be mounted so measuring wheel(s) contact ribbon,
strip or web as it passes over a roller. As an alternative, wheel(s) can be driven
by roller surface next to material being measured.
2. Note: The weight at the Length Sensor unit provides sufficient traction for
accurate operation when mounted, with arm angle from horizonal not
exceeding ±30o.
3. Tension on signal cable can cause wheel(s) to lift. Make sure cable is clamped
to machine frame near the unit and allow slack.
SPECIFICATIONS
ELECTRICAL SPECIFICATIONS
1. SUPPLY VOLTAGE: +8 to +28 VDC (including power supply ripple) @ 50
mA max. (30 mA typ.); Reverse polarity protected.
2. OUTPUTS: NPN Open Collector Transistor, VOH = 30 VDC max., VOL = 1
V max @ 40 mA. Output current is limited to 40 mA. Incremental - Two
square waves in quadrature with Channel A leading B for clockwise rotation.
3. OUTPUT FREQUENCY: Up to 50 KHz
4. OUTPUT DUTY CYCLE: Channel A & B: 50/50 nominal. (See Figure 1,
Note 3)
5. QUADRATURE OUTPUT PHASE: 90° ±15° (See Figure 1, Note 3)
6. CABLE CONNECTIONS: RED = +VDC; BLACK = Common;
WHITE = Channel A Output; GREEN = Channel B Output.
MECHANICAL SPECIFICATIONS
1. MAXIMUM MECHANICAL SPEED: 6000 RPM
2. RADIAL SHAFT LOAD: 15 lbs. max. (66.7N)
3. AXIAL SHAFT LOAD: 15 lbs. max. (66.7N)
4. STARTING TORQUE: 3 oz.-in. (21.2N-mm)
5. MOMENT OF INERTIA:
Single Shaft = 1.03 x 10-4 oz. - in. - sec.2 (7.30 x 10-4N - mm - sec2)
Dual Shaft = 1.30 x 10-4 oz. - in. - sec.2 (9.21 x 10-4N - mm - sec2)
6. OPERATING TEMPERATURE: 0°C to +70°C
7. WEIGHT (LESS CABLE):
ZCH: 14.3 oz (406 g)
ZFH: 22.0 oz (623 g)
ZGH: 22.7 oz (643 g)
ORDERING INFORMATION
MODEL NO.
DESCRIPTION
PPR PART NUMBER
ZCH
Rotary Pulse Generator
(Replaces RPGQ)
100 ZCH0100C
200 ZCH0200C
500 ZCH0500C
100 ZFH0100C
Length Sensor
ZFH
Single Shaft
200 ZFH0200C
(Replaces LSQS)
500 ZFH0500C
ZGH
Length Sensor
Double Shaft
(Replaces LSQD)
100 ZGH0100C
200 ZGH0200C
500 ZGH0500C
Flexible Coupling (1" Length) 0.250" - 0.375" --
RPGFC002
Flexible Coupling (1" Length) 0.375" - 0.375" --
RPGFC
Flexible Coupling (1" Length) 0.375" - 0.500" --
RPGFC003
RPGFC004
Flexible Coupling (1" Length) 0.375" - 6 mm --
RPGFC006
Note: For 25 foot cable, replace the last character of the part number (“C”) with “D”.
For 50 foot cable, replace the last character of the part number (“C”) with “E”.
2