C–Series
CS10.481
48V, 5A, SINGLE PHASE INPUT
15. ENVIRONMENT
Operational temperature
Output de-rating
Storage temperature
Humidity
Vibration sinusoidal
Shock
Altitude
Output de-rating (for altitude)
Over-voltage category
Degree of pollution
-25°C to +70°C (-13°F to 158°F)
3.2W/°C
6W/°C
-40 to +85°C (-40°F to 185°F)
5 to 95% r.H.
2-17.8Hz: ±1.6mm; 17.8-500Hz: 2g
2 hours / axis
30g 6ms, 20g 11ms
3 bumps / direction, 18 bumps in total
0 to 6000m (0 to 20 000ft)
15W/1000m or 5°C/1000m
III
II
2
reduce output power according Fig. 15-1
45-60°C (113°F to 140°F)
60-70°C (140°F to 158°F)
storage and transportation
IEC 60068-2-30
Do not energize while condensation is present
IEC 60068-2-6
IEC 60068-2-27
Reduce output power or ambient
temperature above 2000m sea level.
above 2000m (6500ft), see Fig. 15-2
EN 50178, altitudes up to 2000m
Altitudes from 2000m to 6000m
EN 50178, not conductive
Fig. 15-1 Output current vs. ambient temp.,
Allowable Output
Current at 48V
6A
continuous
5
short
term
4
3
2
1
0
-25
Ambient Temperature
0
20 40 60 70°C
The ambient temperature is defined 2cm below the unit.
Fig. 15-2 Output current vs. altitude
Allowable Output
Current at 48V
6A
BC
5
A
4
short term
3
2 A... Tamb < 60°C
1
B... Tamb < 50°C
C... Tamb < 40°C
0
0
2000
4000
Altitude
6000m
16. PROTECTION FEATURES
Output protection
Output over-voltage protection
Electronically protected against overload, no-load and short-circuits
typ. 56Vdc
max. 60Vdc
In case of an internal power supply defect, a redundant
circuitry limits the maximum output voltage. The output
shuts down and automatically attempts to restart.
Output over-current protection
Degree of protection
Penetration protection
Over-temperature protection
Input transient protection
electronically limited
IP 20
> 3.5mm
yes
MOV
see Fig. 8-1
EN/IEC 60529
e.g. screws, small parts
output shut-down with automatic restart
Metal Oxide Varistor
Internal input fuse
T6.3A H.B.C.
not user replaceable
Note: In case of a protection event, audible noise may occur.
Nov. 2006 / Rev.1.1 DS-CS10.481-EN
All parameters are specified at 48V, 5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
11/20