English
Language : 

05E1 Datasheet, PDF (1/3 Pages) Rectron Semiconductor – SURFACE MOUNT SUPER FAST RECTIFIER VOLTAGE RANGE 50 to 400 Volts CURRENT 0.5 Ampere
RECTRON
SEMICONDUCTOR
TECHNICAL SPECIFICATION
SURFACE MOUNT SUPER FAST RECTIFIER
VOLTAGE RANGE 50 to 400 Volts CURRENT 0.5 Ampere
05E1
THRU
05E6
FEATURES
* High reliability
* Low leakage
* Low forward voltage
* High current capability
* Super fast switching speed
* High surge capability
* Good for switching mode circuit
MECHANICAL DATA
* Case: Molded plastic
* Epoxy: Device has UL flammability classification 94V-O
* Lead: MIL-STD-202E method 208C guaranteed
* Mounting position: Any
* Weight: 0.016 gram
.035 (0.90)
.028 (0.70)
.114 (2.9)
.106 (2.7)
SOD-123F
.077 (1.95)
.069 (1.75)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 oC ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
.008 (0.20)
.030 (0.75)
.022 (0.55)
.150 (3.8)
.142 (3.6)
.053 (1.35)
.047 (1.20)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS (At TA = 25oC unless otherwise noted)
RATINGS
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Volts
Maximum DC Blocking Voltage
Maximum Average Forward Current
at TA = 55oC
Peak Forward Surge Current IFM (surge):8.3 ms single half
sine-wave superimposed on rated load (JEDEC method)
Typical Junction Capacitance (Note 2)
Operating and Storage Temperature Range
SYMBOL
VRRM
VRMS
VDC
IO
IFSM
CJ
TJ, TSTG
05E1
50
35
50
05E2
100
70
100
05E3
150
105
150
05E4
200
140
200
0.5
15
12
-55 to + 150
05E5
300
210
300
05E6
400
280
400
UNITS
Volts
Volts
Volts
Amps
Amps
14
pF
0C
ELECTRICAL CHARACTERISTICS (At TA = 25oC unless otherwise noted)
CHARACTERISTICS
Maximum Forward Voltage at 0.5A DC
Maximum DC Reverse Current
at Rated DC Blocking Voltage
@TA = 25oC
@TA =100oC
Maximum Reverse Recovery Time (Note 1)
NOTES : 1. Test Conditions: IF=0.5A, IR=-1.0A, IRR=-0.25A.
2. Measured at 1 MHZ and applied reverse voltage of 4.0 volts.
3. “Fully ROHS compliant”, “100% Sn plating (Pb-free)”.
SYMBOL
VF
IR
trr
05E1
05E2
05E3
0.95
05E4
5.0
100
35
05E5
05E6
1.25
UNITS
Volts
uAmps
nSec
2006-3
REV:B