Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted
PROTECTIONS
Parameter
Short Circuit Protection (SCP)
Over Voltage Protection (OVP)
Over Load Protection (OLP)
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Condition
3.3Vout
5Vout
Zener Diode Clamp 12Vout
15Vout
% of Iout rated
I/P to O/P
I/P (O/P) to case
500VDC
RP10-E
Series
Value
continuous, automatic recovery
3.9VDC typ.
6.2VDC typ.
15VDC typ.
18VDC typ.
150% max.
1.6kVDC/1 minute
1.6kVDC/1 minute
1GΩ min.
300pF max.
Notes:
Note8: This power module is not internally fused. An input line fuse must always be used.
ENVIRONMENTAL
Parameter
Operating Temperature Range
(Reference Derating Curve)(9)
Maximum Case Temperature
Temperature Coefficient
Thermal Impedance
Operating Humidity
Thermal Shock
Vibration
MTBF(10)
Derating Graph(9,11)
100
Condition
Standard with derating
M1 with derating
vertical direction by natural convection (20LFM)
without Heat-Sink
with Heat-Sink
non-condensing
RP10-4805SE
MIL-HDBK-217F, Full Load
RP10-4805SE with Heat-sink
100
Value
-25°C to +100°C
-40°C to +85°C
+105°C
±0.02%/°C max.
12°C/Watt
10°C/Watt
5% - 95% RH
MIL-STD-810F
MIL-STD-810F
3342 x103 hours
80
80
PD-4
60
40
20
0
-20 0 20 40 60 80 100
-25
77
Ambient Temperature [°C]
continued on next page
REV.: 1/2016
60
40
20
0
-20 0 20 40 60 80 100
-25
81
Ambient Temperature [°C]