Specifications (measured at Ta= 25°C, nominal input voltage, full load and after warm up unless otherwise specified)
Derating Graph
(@ Chamber and natural convection)
RI3
Series
100
80
60
40
Safe Operating Area
20
0
-40 -20
0
20 40 60 80 100 120
85
Ambient Temperature [°C]
Notes:
Note5: For more details, please contact our technical support service at TechsupportAT@recom-power.com.
SAFETY AND CERTIFICATIONS
Certificate Type
CB General Safety
UL General Safety
CAN/CSA General Safety
Report / File Number
E224736-A31
E224736-A32
Standard
IEC60950-1, 2nd Edition, 2013
EN60950-1, 2nd Endition, 2013
UL60950-1, 2nd Edition, 2014
C22.2 No. 60950-1-07, 2nd Edition, 2014
EMC Compliance
EMI (6)
Condition
Notes:
Note6: RI3 Series can meet EN55022 Class A without any external filter.
EMC Filtering - Suggestions for Class B
C2
L1
+Vin
C1
+Vout
DC
Standard / Criterion
EN55022, Class B
DC
-Vin
-Vout
MODEL
C1
C2
L1
RI3-05xxS
4.7µF
470pF/4kV
10µH
RI3-12xxS
4.7µF
470pF/4kV
10µH
RI3-15xxS
RI3-24xxS
2.2µF
470pF/4kV
10µH
ECO-4
REV.: 0/2016
www.recom-power.com