English
Language : 

RP50-241.8S Datasheet, PDF (3/4 Pages) Recom International Power – 50 Watt Single Output
INNOLINE
DC/DC-Converter
Specifications (refer to the standard application circuit, Ta: 25°C)
Vibration
Conducted Emissions
Radiated Emisssions
ESD
Radiated Immunity
Fast Transient
Surge
Conducted Immunity
Case Material
Weight
MTBF Bellcore TR-NWT-000332, Tc=40°C, Io=80% max.
10 ~ 55Hz 2G, 3minutes period, 30minutes analog
EN55022 (Note 7)
EN55022 (Note 7)
EN55022
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
RP50-S
Series
X, Y and Z
Level A
Level B
Level A
Perf. Criteria2
Perf. Criteria2
Perf. Criteria2
Perf. Criteria2
Perf. Criteria2
Open with Aluminium base plate
50g
6
3 x10 hrs
Characteristics
Efficiency VS Output Load
100
90
80
70
60
50
10 20 30 40 50 60 70 80 90 100
Output Power (%) Ta=25°C
48V Input Without Heatsink
110
90
1.) LFM590
70
2.) LFM400
3.) LFM200
50
4.) LFM20
30
10
-40 -20 0
1 2 34
20 40 60 80 100
Ambient Temperature (°C)
48V Input With Heatsink (7G-0022)
110
90
1.) LFM590
70
2.) LFM400
3.) LFM200
50
4.) LFM20
30
10
-40 -20 0
1234
20 40 60 80 100
Ambient Temperature (°C)
142
April-2005
www.recom-international.com