English
Language : 

RACG100 Datasheet, PDF (3/4 Pages) Recom International Power – built in active PFC
RACG100
AC/DC Converter
Specifications (measured at Ta= 25°C, nominal input voltage (115/230VAC), full load and after warm-up)
Series
ENVIRONMENTAL
Parameter
Operating Temperature Range
Temperature Coefficient
Operating Humidity
Moisture Protection
Operating Altitude
MTBF
Derating Graph
Condition
with derating
non-condensing
MIL-HDBK-217F, ground benign, +25°C
100
Value
-20°C to +60°C
0.03%/°C
20% - 90%, RH max.
conformally coated PCB
5000m
200 x 103 hours
80
60
50
40
20
0
-20 0 10 20 30 40 50 60 70 80
Ambient Temperature (°C)
SAFETY AND CERTIFICATIONS
Certificate Type
UL General Safety
CAN/CSA General Safety
Certificate Type (designed to meet)
IEC/EN General Safety
EMC Compliance
EMI Standard
Harmonic Current
Report / File Number
E196683
E196683
Conditions
internal filter
Standard
UL60950-1
C22.2 No. 60950-1
Standard
IEC/EN60950-1
Standard / Criterion
EN55022, Class B
FCC Part 15, Class B
EN61000-3-2, Class A
DIMENSION and PHYSICAL CHARACTERISTICS
Parameter
Case Material
Package Dimension (LxWxH)
Package Weight
www.recom-power.com
Type
continued on next page
REV.: 1/2016
Value
Aluminium
129.0 x 98.0 x 38.0mm
432g typ.
PA-3