English
Language : 

RAC01-GB Datasheet, PDF (3/5 Pages) Recom International Power – 1 Watt Single Output EMC Class B
RAC01-GB
AC/DC Converter
Series
Specifications (measured @ ta= 25°C, nominal input voltage (115/230VAC), full load and after warm-up)
Notes:
Note3: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note4: For operation at 230VAC, an external MOV is recommended. The Varistor should comply with IEC-61051-2. e.g. EPCOS S14 series
LN
U
ENVIRONMENTAL
Parameter
Condition
Operating Temperature Range
Maximum Case Temperature
Temperature Coefficient
Operating Humidity
non-condensing
Operating Altitude (5)
Pollution Degree
Vibration
Shock
MTBF
according to MIL-HDBK-217F, G.B.
+25°C
+70°C
Derating Graph
(@ Chamber and natural convection 0.1m/s)
120
Value
-25°C to + 70°C
+120°C
±0.03%/°C
5% - 90% RH
4000m
PD2
10-150Hz, 2G 10min./1cycle, period 60min. each along x,y,z axes
20G/11ms pulse, 3 times at each x, y, z axes
1691 x 103 hours
424 x 103 hours
100
80
60
50
40
20
0
-25 -20 0
20 40 60 70 80 100
Ambient Temperature [°C]
Notes:
Note5: Recognized by UL for safe operation up to 4000m. High altitude operation may impact the performance and lifetime.
Contact RECOM tech support for advice
www.recom-power.com
REV.: 0/2017
PA-3