English
Language : 

R-78E-1.0 Datasheet, PDF (3/3 Pages) Recom International Power – 1.0 AMP SIP3 Single Output
R-78E-1.0
DC/DC Converter
Series
Specifications (measured at TA= 25°C, full load, nominal input voltage and after warm-up)
DIMENSION and PHYSICAL CHARACTERISTICS
Parameter
Case Material
Potting Material
Package Dimension (LxWxH)
Package Weight
Value
UL94V-0, non-conductive black plastic
UL94V-0, Epoxy
11.6 x 8.5 x 10.4mm
2g typ.
Dimension Drawing (mm)
embossed logo
11.6
8.5
R-78Exx-1.0
xxxx
Marking
R-78Exx-1.0
xxxx
0.7
0.25
3.21
5.08
Bottom View
Ø1.0 +0.15/-0
Top View
2.54
INSTALLATION AND APPLICATION
Standard Application:
+VIN
R-78Exx-1.0
C1
10µF MLCC
(optional)
123
Pin Connections
Pin # Function
1 +Vin
2 GND
3 +Vout
Tolerance: xx.x= ±0.50mm
xx.xx= ±0.25mm
+VOUT
C2
10µF MLCC
(optional)
GND
GND
To protect the converter during power-up, use soft start power supply.
Notes:
Note1: The R-78Exx-1.0 can`t be used as positive to negativ converter.
PACKAGING INFORMATION
Parameter
Type
Packaging Dimension (LxWxH)
Tube
Packaging Quantity
Storage Temperature Range
Value
520 x 18.2 x 11.2mm
42pcs.
-55°C to +125°C
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written
consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 2/2016
I-3