Environmental Specifications
Parameter
Temperature Range (operational)
Ambient
Power Derating (5.1Vout)
+40℃ to +70℃
Storage Temperature Range
Over Temperature Protection
Cooling
Humidity (non condensing)
Power Derating Curve
Conditions
-10℃
-40℃
at 90℃ (automatic recovery at 67℃)
Free-Air convection
---
+70℃
2.25W / ℃
+85℃
95 % rel. H
Notes
1 All specifications typical at Ta=+25℃, resistive load, 115VAC, 60Hz input voltage and after warm-up time rated output current unless
otherwise noted.
2 Ripple & Noise measurement bandwidth is 0~20 MHz
3 These power modules require a minimum output loading to maintain specified regulation, operation under no-load conditions will not
damage the power supplies however they may not meet all listed specifications.
4. Other input and output voltage may be available, please contact us for custom solution.
5 Long term short circuit operation may cause damage to the unit.
6 Specifications are subject to change without notice
DS_AA60S_06172014