RPP40-2412SW Datasheet, PDF (2/5 Pages) Recom International Power – 40 Watt 4:1 Ribbed Style Single Output
RPP40-2412SW
DC/DC Converter
Series
Specifications (measured @ ta= 25°C, nominal input voltage, full load and after warm-up)
REGULATIONS
Parameter
Output Voltage Accuracy
Line Voltage Regulation
Load Voltage Regulation
Transient Response
Transient Peak Deviation
Trimming Output Voltage
Condition
50% load
low line to high line
10% to 100% load
25% load step change, ΔIo/Δt=2.5A/us
25% load step change, ΔIo/Δt=2.5A/us
Value
±1.5% max.
±0.3% max.
±0.5% max.
800µs typ.
±2%Vout max.
±10% typ.
Trimming Output Voltage
Only the single output converters have a trim function that allows users to adjust the output voltage from +10% to -10%, please refer to
the trim table that follow for details. Adjustment to the output voltage can be used with a simple fixed resistor as shown in Figures 1 and 2.
A single fixed resistor can increase or decrease the output voltage depending on its connection. Resistor should be located close to the converter.
If the trim function is not used, leave the trim pin open.
Trim adjustments higher than the specified range can have an adverse effect on the converter´s performance and are not recommended.
Excessive voltage differences between output voltage sense voltage, in conjunction with trim adjustment of the output voltage; can cause
the OVP circuitry to activate. Thermal derating is based on maximum output current and voltage at the converter´s output pins. Use of
the trim and sense function can cause output voltages to increase, thereby increasing output power beyond the converter´s specified rating.
Therefore: (Vout at Pins) X (Iout) ≤ rated output power.
+VIN
CTRL
-VIN
+VOUT
TRIM
-VOUT
RTRIMUP
LOAD
Figure 1. Trim connections to increase
output voltage using fixed resistors
Trim up resistor value (KW)
Vout 1% 2% 3% 4% 5% 6% 7% 8% 9% 10%
12VDC 270 120 70 45.2 30.1 19.8 12.8 7.52 3.31 0
+VIN
CTRL
-VIN
+VOUT
TRIM
-VOUT
RTRIMDOWN
LOAD
Figure 2. Trim connections to decrease output
voltage using fixed resistors
Trim down resistor value (KW)
Vout -1% -2% -3% -4% -5% -6% -7% -8% -9% -10%
12VDC 270 120 70 45.2 30.1 19.8 12.8 7.52 3.31 0
PROTECTIONS
Parameter
Output Power Protection (OPP) (2)
Over Voltage Protection (OVP)
Over Temperature Protection (OTP)
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Condition
Hiccup Mode
10% load
case temperature
I/P to O/P, at 70% RH
I/P to Case, O/P to Case
I/P to O/P , at 70% RH
I/P to O/P
Value
120% typ.
120% typ.
120°C, auto-recovery
2250VDC / 1 Minute
1500VDC / 1 Minute
100MW min.
1500pF typ.
Notes:
Note2:
Note3:
combines Over Load Protection and Short Circuit Protection
This Power Module is not internally fused. A input fuse must be always used. Recommended Fuse: T6.3A