English
Language : 

RAC05-C Datasheet, PDF (2/3 Pages) Recom International Power – 5 Watt Single / Dual Output
POWERLINE
AC/DC-Converter
RAC05-S_DC
Series
Specifications (measured at TA 25°C, full load after warm-up)
Potting Material
Relative Humidity
Package Weight
Packing Quantity
MTBF (25°C)
(65°C)
Emissions
Immunity
Certifications:
UL General Safety
cUL
EN General Safety
CE
Single / Dual
Single Output
Dual Output
Wired Version
Using MIL-HDBK 217F
Using MIL-HDBK 217F
CE
EMC
Harmonics
Flicker
ESD
RS
EFT
Surge
CS
PMF
Voltage Variations
Report: E224736
Report: E224736
Report: SPCLVD1211033-1
Epoxy UL94V-0
95% RH max.
35g / 38g
10pcs
9pcs
1pc
>400 x 10³ hours
>200 x 10³ hours
EN 55022: 2006 + A1: 2007 / Class B
EN 55024:1998 + A1:2001 + A2:2003
EN 61000-3-2:2006 / Class A
EN 61000-3-3:1995 + A1:2001 +A2:2005
IEC 61000-4-2 / Criterion B
IEC 61000-4-3 / Criterion A
IEC 61000-4-4 / Criterion B
IEC 61000-4-5 / Criterion B
IEC 61000-4-6 / Criterion A
IEC 61000-4-8 / Criterion A
IEC 61000-4-11 / Criteria B + C
UL-60950-1, 2nd Edition
C22.2 No. 60950-1-07, 2nd Edition
EN-60950-:2006 + A12:2011
EN55022 Class B
Notes:
Note1: Measured @230VAC / 50Hz / Ta=25°C with constant resistant mode at full load.
Note2: If used @115VAC / 60Hz with full load, max. capacitive load is less, please contact RECOM for detailed information.
Note3: Start up only is guaranteed at temperatures down to -25°C. Other specifications may not be met.
Typical Characteristics
Vin=115VAC
Vin=230VAC
85
12V
80
75
5V
70
24V
65
60
0 10 20 30 40 50 60 70 80 90 100
80
12V
75
70
65
5V
24V
60
55
50
0 10 20 30 40 50 60 70 80 90 100
Load (%)
Input Voltage Derating Graph
100% 90V, 100%
264V, 100%
Load (%)
90%
80% 80V, 80%
Safe Operating Area
70%
80
130
180
230 280
Input Voltage (VAC) Ta=25°C
www.recom-power.com
REV: 0/2015
PA-31