English
Language : 

R1DA Datasheet, PDF (2/3 Pages) Recom International Power – 1 Watt SMD Dual Independent Outputs
ECONOLINE
DC/DC-Converter
Specifications (measured at TA = 25°C, nominal input voltage, full load and after warm-up
Package Weight
Packing Quantity
MTBF
Using MIL-HDBK 217F (+25°C)
Using MIL-HDBK 217F (+85°C)
Detailed Information see Application Notes chapter „MTBF“
Certifications
EN General Safety
Report: 10010807-2009
Conducted Emissions
Radiated Emissions
UL General Safety
Report: E358085
R1DA
Series
1.2g
33 pcs per tube / 500 pcs per reel
1045 x 10³ hours
183 x 10³ hours
EN-60950-1. 2nd Edition
EN55022 Class B with Filter
EN55022 Class B with FIlter
UL60950-1, 2nd Edition
Notes
Note 1: Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter.
Tolerance Envelope
+10%
+5%
V Nom.
Typical Load Line
+5%
– 1%
– 5%
10%
50%
100%
Output Load Current (%)
Typical Characteristics
R1DA-xx0505
Efficiency / Load
100
050505
80
3.30505
60
40
120505
20
0
0% 20%
40% 60%
Total Output Current (%)
Deviation / Load
25.000
20.000
80% 100%
15.000
10.000
5.000
3.30505
050505
0
-5.000 120505
-10.000
0% 20% 40% 60%
Total Output Current (%)
80% 100%
www.recom-power.com
REV: 0/2015
R1DA-xx1212
Efficiency / Load
100
3.31212
80
121212
60
051212
40
20
0
0% 20%
40% 60%
Total Output Current (%)
Deviation / Load
25.000
80% 100%
20.000
15.000
10.000
5.000
3.31212
051212
0
-5.000
121212
-10.0000% 20% 40% 60%
Total Output Current (%)
80% 100%
E-77