Specifications (measured at TA = 25°C, nominal input voltage, full load and after warm-up)
Efficiency at Full Load
See Selection Guide
Minimum Load = 0%
Specifications valid for 10% minimum load only.
Isolation Voltage
(tested for 1 second)
1000VDC
(rated for 1 minute***)
500VAC / 60Hz
Isolation Voltage
H-Suffix
(tested for 1 second)
3000VDC
H-Suffix
(rated for 1 minute***)
1500VAC / 60Hz
Isolation Capacitance
R1S, R1S8, R1D, R1D10
15pF min. / 70pF max.
R1S12, R1D12
10pF min. / 75pF max.
Isolation Resistance
10 GΩ min.
Short Circuit Protection
1 Second
P-Suffix
Continuous
Operating Temperature Range (free air convection)
-40°C to +100°C (see Graph)
Storage Temperature Range
-55°C to +125°C
Reflow Temperature
ROHS compliant
245°C (30 sec), Peak 255°C (5 sec) max.
Vapour Phase Process
(for more details see Application Notes)
230°C (90 sec) max.
Relative Humidity
95% RH
Humidity Susceptibility Test
1000 hrs / 90% humidity / +85°C ambient
Package weight
R1S
1.0g
R1S8
1.1g
R1S12, R1D, R1D10, R1D12
1.2g
Packing Quantity
R1S, R1S8
40 pcs per Tube
R1S12, R1D, R1D10, R1D12
33 pcs per tube
All Types
500 pcs per Reel
} MTBF (+25°C) Detailed Information see
using MIL-HDBK 217F
(+85°C) Application Notes chapter "MTBF" using MIL-HDBK 217F
4275 x 103 hours
1365 x 103 hours
Certifications
CB Test Report
Report: US/14402A/UL
IEC 60950-1:2001 1st Ed.
UL General Safety
Report: E358085
UL 60950-1 2nd Ed.
CUL General Safety
C22.2 No. 60950-1-03
EN Medical Safety
Report: MDD1205098-2 + RM1205098-2
IEC/EN 60601-1 3rd Edition
Medical Report + ISO14971 Risk Assessment
EN General Safety
Report: SPCLVD1211033-3
EN60950-1: 2006 + A12:2011
Conducted / Radiated Emissions
EN55022
Level A
***Any data referred to in this datasheet are of indivative nature and based on our practical experience only. For further details, please refer to our Application Notes.
Notes
Note 1: Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter.
Typical Characteristics
R1S**-xx05
R1D**-xx05
Tolerance Envelope
+10%
+5%
Typical Load Line
+5%
V Nom.
– 1%
– 5%
10%
50%
100%
Output Load Current (%)
Efficiency / Load
100
3.305
80
1205
60
0505
40
20
0
0% 20% 40% 60% 80%
Total Output current (%)
Deviation / Load
25.000
20.000
15.000
10.000
3.305
0505
5.000
0.000
-5.000
1205
-10.000
0% 20% 40% 60% 80%
Total Output current (%)
100%
100%
Efficiency / Load
100
0505
80
1205
60
40
3.305
20
0
0% 20% 40% 60% 80%
Total Output current (%)
Efficiency / Load
100
0505
1205
80
100%
60
40
3.305
20
0
0% 20% 40% 60%
Total Output current (%)
80% 100%
www.recom-international.com