R05X12 Datasheet, PDF (2/4 Pages) Recom International Power – EUROLINE - DC/DC - CONVERTER
EUROLINE - DC/DC-Converter
RxxX and RxxY Series, 1 Watt, SIP7/DIP14, Regulated / Isolated (Single Output)
Typical Isolation Capacitance (pF)
Part Number
Output Voltage (V)
05
09
12
13
15
R05X/Yxx
28
32
33
31
39
R12X/Yxx
48
63
68
–
69
R24X/Yxx
84
106
132
–
152
R48X/Yxx
54
75
92
–
109
Electrical Specifications (measured at TA = 25°C, at nominal input voltage and rated output current unless otherwise specified)
Input Voltage Range VIN (continuous operation)
5V types
12V types
24V types
48V types
5V±5%
12V±5%
24V±5%
48V±5%
Load Voltage Regulation (10% load to 100% full load)
0.9% typ. / 1.5% max.
Line Voltage Regulation (depending on the Type)
Output Voltage Accuracy (control pin open circuit)
0.25% / 1.0% of VIN
±5%
Input Reflected Ripple (20MHz band limited)
40mVp-p max.
Output Ripple (20MHz band limited)
60mVp-p max.
Insulation Resistance (at 500VDC)
100MΩ min.
Efficiency (at full load)
5V output types
9V, 12V and 15V output types
45% min. / 50% typ.
55% min. / 62% typ.
Temperature Drift (VOUT)
Temperature Rise above Ambient (at full load)
0.03% per °C max.
8°C max.
Switching Frequency at Full Load (depending on the type)
80kHz typ.
Package Weight
SIP and DIP 5/12/24V types
2.3 g
SIP and DIP 48V types
2.9 g
MTTF 1) (depending on the type)
–25°C
+25°C
+70°C
165kHrs min. / 2406kHrs max.
135kHrs min. / 1307kHrs max.
69kHrs min. / 144kHrs max.
1). Calculated using MIL-HDBK-217F with nominal input voltage at full load.
Please contact us, if you need exact parameters for the converter you have selected.