English
Language : 

R0.5S-D Datasheet, PDF (2/8 Pages) Recom International Power – Approved for Medical Applications
ECONOLINE
DC/DC-Converter
R0.5S_D
Series
Specifications (measured at TA = 25°C, nominal input voltage, full load and after warm-up)
Input Voltage Range
±10% max.
Voltage Set Accuracy
100% Load/nominal Vin
-1% typ. / ±5% max.
Line Regulation
Low Line to High Line @ max. Load
1.2% typ.
Load Regulation
5V output
6% typ. / 15% max.
(10% to 100% Load)
12/15V output
5%typ. / 10% max.
Ripple & Noise @ 20MHz BW
50 mVp-p typ. / 100mVp-p max.
Efficiency at Full Load
70% min.
Operating Temperature
-40°C to +100°C
Storage Temperature
-55°C to +125°C
Isolation Voltage
(tested for 1 second)
1000VDC
(rated for 1 minute***)
500VAC / 60Hz
Isolation Voltage
H-Suffix
(tested for 1 second)
3000VDC
H-Suffix
(rated for 1 minute***)
1500VAC / 60Hz
Isolation Capacitance
75pF max.
Isolation Resistance
Viso = 500V
10 GΩ min.
Humidity
95% max.
Operating Frequency
Vin (nom.)
20kHz min. / 50 kHz typ. / 90 kHz max.
Short-Circuit Protection
1 Second
MTBF
Using MIL-HDBK 217F (+100°C)
1003 x 10³ hours
Using MIL-HDBK 217F (+25°C)
3962 x 10³ hours
Detailed Information see Application Notes chapter „MTBF“
Weight
Single Types
1.0 g
Dual Types
1.2 g
Certification
UL General Safety
Report: E358085
UL 60950-1 2nd Ed.
***Any data referred to in this datasheet are of indicative nature and based on our practical experience only. For further details, please refer to our Application Notes.
Notes
Note1: Maximum capacitive load is defined as the capacitive load that will allow start up in under 1second without damage to the converter.
Typical Characteristics
Tolerance Envelope
Tolerance Envelopes
+10%
+5% Typical load line
+5%
VNOM
-1%
-5%
10%
50%
100%
+Vout and -Vout load current (%)
www.recom-power.com
REV: 0/2015
E-17