English
Language : 

R0.25S Datasheet, PDF (2/4 Pages) Recom International Power – Full Power at 100°C Ambient Temperature
ECONOLINE
DC/DC-Converter
R0.25S_R0.25D
Series
Specifications (measured at TA = 25°C, nominal input voltage, full load and after warm-up)
Efficiency at Full Load
60%-70%
Minimum Load = 0%
Specifications valid for 10% minimum load only
Isolation Voltage
(tested for 1 second)
1000VDC
(rated for 1 minute***)
500VAC / 60Hz
H-Suffix
(tested for 1 second)
3000VDC
(rated for 1 minute***)
1500VAC / 60Hz
R0.25DA Output/ Output Isolation Voltage
(tested for 1 second)
1000VDC
Isolation Capacitance
75pF max.
Isolation Resistance
Short Circuit Protection
Viso=500V
10 GΩ min.
1 Second
P-Suffix
Continuous
Operating Temperature Range (free air convection)
-40°C to +100°C (see Graph)
Storage Temperature Range
-50°C to +125°C
Reflow Temperature
ROHS compliant
245°C (30 sec), Peak 255°C (5 sec) max.
Vapor Phase Process
(for more details see Application Notes)
230°C (90 sec) max.
Relative Humidity
95% RH
Humidity Susceptibility Test
1000 hrs / 90% humidity / +85°C ambient
Package weight
1.0g (R0.25S), 1.2g (R0.25D(A))
Packing Quantity
R0.25S, R0.25S8
40 pcs per Tube
R0.25S12, R0.25D, R0.25D10
33 pcs per tube
R0.25D12, R0.25DA
33 pcs per tube
All Types
500 pcs per Reel
} MTBF (+25°C) Detailed Information see
(+85°C) Application Notes chapter "MTBF"
using MIL-HDBK 217F
using MIL-HDBK 217F
4423 x 103 hours
2161 x 103 hours
Certifications
Conducted / Radiated Emissions
EN55022
Level A
CB Test Report
Report: US/14402A/UL
IEC 60950-1:2001 1st Ed.
UL General Safety
Report: E358085
UL 60950-1 2nd Ed.
CUL General Safety
C22.2 No. 60950-1-03
EN Medical Safety
Report: MDD1205098-2 + RM1205098-2
IEC/EN 60601-1 3rd Edition
Medical Report + ISO14971 Risk Assessment
EN General Safety
Report: SPCLVD1211033-3
EN60950-1:2006 + A12:2011
Notes
***Any data referred to in this datasheet are of indicative nature and based on our practical experience only. For further details, please refer to our Application Notes.
Note 1: Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter.
Typical Characteristics
Tolerance Envelope
+10%
+5%
V Nom.
Typical Load Line
+5%
– 1%
– 5%
R0.25S**-xx05
Efficiency / Load
100
80
0505
60
3.305
40
20
1205
0
0% 20% 40% 60%
Total Output current (%)
80% 100%
R0.25D**-xx05
Efficiency / Load
100
80
0505
60
3.305
40
1205
20
0
0% 20% 40% 60%
Total Output current (%)
80% 100%
10%
50%
100%
Output Load Current (%)
www.recom-power.com
Deviation / Load
25.000
20.000
15.000
10.000
3.305
0505
5.000
0.000
-5.000
-10.000
1205
0% 20% 40% 60%
Total Output current (%)
80%
100%
REV: 0/2015
Deviation / Load
25.000
20.000
15.000
10.000
1205
3.305
5.000
0.000
-5.000
-10.000
0505
0% 20%
40%
60%
Total Output current (%)
80%
100%
E-9