R-78B-1.0 Datasheet, PDF (2/4 Pages) Recom International Power – 1.0 AMP SIP3 Single Output
INNOLINE
DC/DC-Converter
R-78Bxx-1.0
(L) Series
Specifications (refer to the standard application circuit, Ta: 25°C, minimum load = 10%)
Characteristics
Input Voltage Range
Output Voltage Range (for customized parts)
Output Current (see Note 1)
Output Current Limit
Short Circuit Input Current (Vin = 24V)
Internal Power Dissipation
Short Circuit Protection
Output Voltage Accuracy (At 100% Load)
Line Voltage Regulation (Vin = min. to max. at full load)
Load Regulation (10% to 100% full load)
Dynamic Load Stability (with Output Capacitor=100µF)
Ripple & Noise (without Output Capacitor)
(10% to 100% full load)
Temperature Coefficient
Max capacitance Load
Switching Frequency
Quiescent Current
Input Reflected Ripple Current
Operating Temperature Range
Operating Case Temperature
Storage Temperature Range
Case Thermal Impendance
Thermal Shutdown
Relative Humidity
Thermal Shutdown
Case Material
Package Weight
Packing Quantity
Conducted Emissions
Radiated Emissions
ESD
Safety Certification
} MTBF (+25°C) Detailed Information see
. (+71°C) Application Notes chapter "MTBF"
Conditions
1.5V, 1.8V
2.5V to 15.5V
All Series
All Series
All Series
All Series
All Series
1.5V to 6.5V
9V to 15.5V
1.5V to 6.5V
9V to 15.5V
100% <-> 50% load
Transient Recovery Time
1.5V to 6.5V
9V to 15.5V
-40°C ~ +85°C ambient
Vin = min. to max. at 0% load
All Series
Internal IC junction
Internal IC junction
EN55022
EN55022
EN61000-4-2
EN-60950-1
using MIL-HDBK 217F
using MIL-HDBK 217F
Min.
4.75V
4.75V
Typ.
Max.
25
26V abs. max.
32
34V abs. max.
1.5V
15.5V
0mA*
1000mA
2000mA
60mA
0.65W
Continuous, automatic recovery
±2%
0.2%
0.1%
0.4%
0.25%
±100mV
1.0ms
15mVp-p
25mVp-p
±3%
0.4%
0.2%
0.6%
0.4%
±150mV
1.5ms
20mVp-p
35mVp-p
0.015%/°C
220µF
280kHz
330kHz
380kHz
5mA
7mA
150mA
200mAp-p
-40°C
+85°C
+100°C
-55°C
+125°C
60°C / W
+160°C
95% RH
+160°C
Epoxy with Non-Conductive Plastic Case (UL94V-0)
4g
42 pcs per Tube
Class B
Class B
Class A
6584 x 10³ hours
1139 x 10³ hours
*Note: Operation under no load will not damage these devices, however they may not meet all specifications. A minimum load of 10mA is recommended