English
Language : 

AA10S Datasheet, PDF (2/4 Pages) Delta Electronics, Inc. – 10W Single Output AC/DC Power Module
Output Characteristics
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise (20MHz)
Minimum Load
Over Voltage Protection
Temperature Coefficient
Overshoot
Current Limitation
Short Circuit Protection
Conditions
Min.
Typ.
Max.
Unit
---
±1.0
±2.0
%
Vin=Min. to Max.
---
±0.5
±1.0
%
Iout=Min. to Max.
---
±0.5
±1.0
%
3.3 & 5.0VDC Output Models
%VPP of
---
1.5
1.8
V
o
Other Output Models
%VPP of
---
0.8
1.0
V
o
---
10
---
%Inom.
Zener diode clamp
---
120
---
% of Vo
---
±0.01 ±0.02
%/℃
---
---
5
% Vout
Foldback, auto-recovery
105
---
(long term overload condition may cause damage)
---
%Inom.
Hiccup mode, indefinite (automatic recovery)
General Characteristics
Parameter
Conditions
Min.
Typ.
Max.
Unit
I/O Isolation Voltage
I/O Isolation Resistance
Input to Output, 60 Seconds
500 VDC
3000
100
---
---
VACrms
---
---
MΩ
Switching Frequency
---
125
---
KHz
Hold-up Time
---
20
---
ms
MTBF (calculated)
MIL-HDBK-217F@25℃, Ground Benign
300,000
---
---
Hours
EMC Emission
Conducted and radiated
Standard
EN61000-4-2
EN 55011, class B, EN 55022, class B, FCC part 15, class B
Specification Requirement
Performance
Criteria
Air ±8KV Cont. ±4KV
B
EN61000-4-3
80~1000MHz, 10V/m 80% AM, 1KHz modulation
A
EMC Immunity according
EN61000-6-1
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
AC port ±2KV DC, SL, TL ±2KV not less than 1
B
min.
1.2/50uS(8/20uS) AC dif. ±1KV DC ±0.5KV
B
0.15~80MHz, 10Vrms (functional earth ports
included)
B
80% AM, 1KHz modulation
50Hz/60Hz, 30A/m
A
EN61000-4-11
30%, 10ms
B
60%, 100ms, 95%, 5000ms
C
Protection Class II
According IEC/EN 60536
Safety Approvals
cUL/UL 60950-1,IEC/EN 60950-1
Recommended Input Fuse
External Fuse (Recommended)
All Models
1.5A Slow – Blow Type
DS_AA10S_06162014
E-mail: DCDC@delta.com.tw