English
Language : 

RP100H-RW Datasheet, PDF (10/15 Pages) Recom International Power – 4:1 Wide Input Range
RP100H-RW
DC/DC Converter
Series
Specifications (measured @ ta= 25°C, nominal input voltage, full load and after warm-up)
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Information Technology Equipment, General Requirements for Safety
IEC/EN Information Technology Equipment - General Requirments for Safety
Railway Applications - Electrical Equipment used on rolling stock
Report / File Number
E196683
TW1608033-001, TW1608036-001,
TW1608037-001, TW1608079-001
16A081501E-C
Standard
UL60950-1, 2nd Edition, 2014
CSA C22.2 No. 60950-1-07, 2014
IEC60950-1, 2nd Edition. 2005
EN60950-1, 1st Edition, 2006
EN50155, 2007
EMI Compliance
Information technology equipment - Radio disturbance characteristics - Limits and
methods of measurement
Industrial, scientific and medical equipment - Radio frequency disturbance
characteristics - Limits and methods of measurement
ESD Electrostatic discharge immunity test
Radiated, radio-frequency, electromagnetic field immunity test
Fast Transient and Burst Immunity(6)
Surge Immunity(6)
Immunity to conducted disturbances, induced by radio-frequency fields
Power Magnetic Field Immunity
Condition
with external components
Air ±8kV and Contact ±6kV
20 V/m
±2kV
EN55024 & EN50155 ±2kV
10 Vr.m.s
100A/m continuous; 1000A/m 1s
Standard / Criterion
EN55022, Class A and Class B
EN55011, Class A and Class B
EN61000-4-2, Criteria A
EN61000-4-3, Criteria A
EN61000-4-4, Criteria A
EN61000-4-5, Criteria A
EN61000-4-6, Criteria A
EN61000-4-8, Criteria A
Notes:
Note6:
An external input filter capacitor is required if the module has to meet EN61000-4-4 and EN61000-4-5.
The 24Vin and 48Vin version recommend 2pcs of aluminium elecrolytic capacitor to connect in parallel.
Recom suggest: Nippon Chemi-con KY series, 220µF/100V.
The 110Vin version recommend 2pcs of aluminium electrolytic capacitor to connect in parallel.
Recom suggest: Nippon Chemi-con KXJ series, 150µF/200V
4xxSRW, Class A
8xxSRW, ClasEsMA I Filtering according to EN55022/11 Class A and EN50121-1 (24Vin and 48Vin)
C10
Fuse
L1
+VIN
C1 C2 C3
C4 C5 C6 C7
Case
-VIN
C8 C9
C11
C12 C13
10xxSRW, Class A
Fuse
Shield Plane
MODEL
C1, C2, C4
L1
RP100H-24xxSRW
470µF, 50V
Al cap. (lie down) Chemi-con KY
220µF, 100V
C1 RP1C200H-4C38xxSRW ACl8cap.C(9lie dCo1w0n) Chemi-con KY
C3, C6, C7
C8, C9,CC118 0,
C11, C13
4.7µF, 50V 1000pF, 3kV
1812 MLCC 1808 MLCC
2.2µF, 100V 1000pF, 3kV
1812 MLCC 1808 MLCC
Case
C12
3300pF, 3kV
1808 MLCC
1000pF, 3kV
1808 MLCC
L1
156µH
CMC
224µH
CMC
PCB7-10C6
C5 C4
continued on next page
C11 C12 C13REVC.:114/2016
C17
C19 C16 C15wwCw2.0recom-power.com