English
Language : 

RY-1205D Datasheet, PDF (1/2 Pages) Recom International Power – ECONOLINE - DC/DC-Converter, 1 Watt, DIP14/SIP7, Regulated (Dual Output)
ECONOLINE - DC/DC-Converter
RX and RY Series, 1 Watt, DIP14/SIP7, Regulated (Dual Output)
Features
● Controllable Output
● 1kVDC Isolation
● UL94V-0 Package Material
● No Heatsink Required
● Fully Encapsulated
● No External Components
● Toroidal Magnetics
Selection Guide
Part
Number
DIP14
Part
Number
SiP7
RX-XX05D
RY-XX05D
RX-XX09D
RY-XX09D
RX-XX12D
RY-XX12D
RX-XX15D
RY-XX15D
RX-XX24D
RY-XX24D
Input
Voltage
(VDC)
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
Output
Voltage
(VDC)
±5 V
±9 V
±12 V
±15 V
±24 V
Output
Current
(mA)
±100
±55
±42
±33
±21
Efficiency
(%)
54
58
62
65
65
Specifications (Core Operating Area) and Operating Temperature / Derating-Graph
Input Voltage
±5%
Input Filter
Capacitor Type
Output Voltage Accuracy
±0.5%
Line Voltage Regulation
±0.05% / ±1.0%
Load Voltage Regulation (20% to 100% full load)
±0.5% / ±1.0%
Ripple and Noise (20MHz limited)
100mVp-p max.
Efficiency at Full Load
50% min.
Isolation Voltage
1.000VDC min.
Isolation Resistance (Viso = 500VDC)
10 GΩ min.
Isolation Capacitance
40pF min./72pF max.
Short Circuit Protection
1 Second
Switching Frequency at Full Load
30kHz min. / 88kHz max.
Operating Temperature
-40°C to +71°C (see Graph)
Storage Temperature
-55°C to +125°C
Package Weight
RX types
2.7g
RY types
2.8g
2.0
1.5
1.0
Safe Operating Area
0.5
0
-40 0
50 100 150
71 125
Operating Temperature ˚C
Typical Applications
Flash PROM Programming Voltage Control
Vcc 1
2
GND
RY-XX12
CTRL
4
5
6
1kΩ
Vout = 12V, TTL = 0V
Vout = 1.2V, TTL = 1V
TTL Input
2N2219, BC107, ZTX451
or Similar Transistors capable of
0V
0V Sinking 50mA Continuous Current
Normal Isolated Regulated Output
Vcc
1
2
GND
RY-XX12
CTRL
4
5
NC
0V
6 Vout
EC 40
August 2002
www.recom-international.com