English
Language : 

RXXP2XX Datasheet, PDF (1/4 Pages) Recom International Power – EN-60601 for Medical Applications
Features
Unregulated
Converters
● UL/CSA and EN Safety certified
● EN-60601 for Medical Applications
● Isolation 6.4kVDC
● Optional Continuous Short Circuit Protected
● Unique Transformer System
● Compact SIP7 Package
● /X2 Version with >9mm Input/Output Clearance
● Suitable for IGBT Applications
● Very Low Isolation Capacitance
Description
The RxxP2xxS_D Series of DC/DC Converters are certified to UL/CSA-60950 and UL/CSA
60601as well as EN-60950 and EN60601. This makes them ideal for medical and safety
applications where approved isolation is required. The /X2 version has an input/output
clearance of more than 9mm.
Selection Guide
Part
Numbe
SIP 7
RxxP23.3S*
RxxP205S*
Input
Voltage
(VDC)
5, 12, 15, 24
5, 12, 15, 24
Output
Voltage
(VDC)
3.3
5
Output
Current
(mA)
600
400
Efficiency
Std
(%)
70
70-75
Max
Capacitive
Load(1)
3300µF
1200µF
RxxP209S* 5, 12, 15, 24
9
222
70-75
1200µF
RxxP212S* 5, 12, 15, 24
12
167
70-75
680µF
RxxP215S* 5, 12, 15, 24
15
132
75-80
680µF
RxxP23.3D* 5, 12, 15, 24
±3.3
RxxP205D* 5, 12, 15, 24
±5
RxxP209D* 5, 12, 15, 24
±9
RxxP212D* 5, 12, 15, 24
±12
±300
±200
±111
±85
70
70-75
70-75
70-75
±1500µF
±470µF
±470µF
±330µF
RxxP215D* 5, 12, 15, 24
±15
±66
75-80
±330µF
RxxP21509D* 5, 12, 24
+15/-9
+67/-111
70-82
±330µF
xx = Input Voltage. Other input and output voltage combinations available on request.
* add Suffix “P” for Continuous Short Circuit Protection, e.g. R05P205S/P, R05P205D/P
* add Suffix “/X2” for single output with alternative pinout, e.g. R05P205S/X2, R05P205S/P/X2
Specifications (measured at TA = 25°C, nominal input voltage, full load and after warm-up)
Input Voltage Range
±10%
Output Voltage Accuracy
±5%
Line Voltage Regulation
1.2%/1% of Vin typ.
Load Voltage Regulation
3.3, 5V output types
15% max.
(10% to 100% full load)
other output types, RxxP21509D
10% max.
Output Ripple and Noise (20MHz BW)
200mVp-p max.
Operating Frequency
20kHz min. / 50kHz typ. / 85kHz max.
RxxP21509D
20kHz min. / 50kHz typ.
Efficiency at Full Load
65% min. / 80% max.
Minimum Load = 0%
Specifications valid for 10% minimum load only.
Isolation Voltage
(tested for 1 second)
6400VDC
(rated for 1 minute**)
3200VAC / 60Hz
Isolation Capacitance
1.5pF min / 10pF max.
Isolation Resistance
15 GΩ min.
Short Circuit Protection
1 Second
P-Suffix
Continuous
continued on next page
**Any data referred to in this datasheet are of indicative nature and based on our practical experience only. For further details, please refer
to our Application Notes.
E-96
REV: 2/2015
ECONOLINE
DC/DC-Converter
with 3 year Warranty
2 Watt
SIP 7 Single &
Dual Output
RoHS
2011/65/EU
6/6
E-358085
EN-60950-1 Certified
IEC/EN-60601-1 Certified*
UL/CSA 60950-1 Certified*
* +15/-9 Version excluded
RxxP2xx
Derating-Graph
(Ambient Temperature)
100
80
60 Safe Operating Area
40
20
0
-40
0
50 90 100 150
95
Operating Temperature °C
Refer to Application Notes
www.recom-power.com