RUZ Datasheet, PDF (1/3 Pages) Recom International Power – 2 Watt SIP7 Isolated Dual Output
Features
Unregulated
Converters
● Dual Output from a Single Input Rail
● Input/Output Isolation 1kVDC
● Output/Output Isolation 1kVDC
● Power Sharing on Outputs
● UL94V-0 Package Material
● Toroidal Magnetics
● No Extern. Components Required
● Efficiency to 85%
ECONOLINE
DC/DC-Converter
RUZ
Series
Selection Guide
Part
Number
SIP 7
RUZ-xx3.33.3
RUZ-xx0505
RUZ-xx0509
RUZ-xx0512
RUZ-xx0515
RUZ-xx0909
RUZ-xx1212
RUZ-xx1515
RUZ-xx2424
xx = Input Voltage
Input
Voltage
(VDC)
5, 9, 12, 24
5, 9, 12, 24
5, 9, 12, 24
5, 9, 12, 24
5, 9, 12, 24
5, 9, 12, 24
5, 9, 12, 24
5, 9, 12, 24
5, 9, 12, 24
Output
Voltage
(V1VDC)
3.3
5
5
5
5
9
12
15
24
Output
Voltage
(V2VDC)
3.3
5
9
12
15
9
12
15
24
Output
Current
(mA)
303/303
200/200
200/111
200/84
200/66
111/111
84/84
66/66
42/42
Efficiency
(%)
70
70-82
70-82
70-82
70-82
82-84
82-84
82-84
80-85
2 Watt
SIP7
Isolated
Dual Output
Specifications (Core Operating Area)
Input Voltage Range
±10%
Output Voltage Accuracy
±5%
Line Voltage Regulation
1.2%/1% of Vin max.
Load Voltage Regulation
(10% to 100% full load)
3.3V output types
5V output type
9V, 12V, 15V, 24V output types
20% max.
15% max.
10% max.
Output Ripple and Noise (20MHz limited)
150mVp-p max.
Operating Frequency
35kHz min. / 50kHz typ. / 85kHz max.
Efficiency at Full Load
70% min. / 80% typ.
No Load Power Consumption
Isolation Voltage
1)
Rated Working Voltage 1)
163mW min. / 223mW typ. / 350mW max.
(tested for 1 second)
(long term isolation)
1.000VDC min.
see Application Notes
Isolation Capacitance
40pF min. / 120pF max.
Isolation Resistance
10 GΩ min.
Short Circuit Protection
1 Second
Operating Temperature Range (free air convection)
-40°C to +85°C (see Graph)
Storage Temperature Range
-55°C to +125°C
Relative Humidity
MSL Level 1
95% RH
Package Weight
} MTBF (+25°C) Detailed Information see
using MIL-HDBK 217F
(+85°C) Application Notes chapter "MTBF" using MIL-HDBK 217F
2.8g
988 x 103 hours
135 x 103 hours
1) Input/Output and Output V1/Output V2
74
April-2005
Derating-Graph
(Ambient Temperature)
100
80
60 Safe Operating Area
40
20
0
-40
0
50
100 150
85
Operating Temperature °C
www.recom-international.com