English
Language : 

RPP20-W Datasheet, PDF (1/4 Pages) Recom International Power – 20 Watt Single & Dual Output
Features
ICE
Technology*
● Up to 97°C Ambient, no derating
● 120°C Maximum Case Temperature
● -45°C Minimum OperatingTemperature
● Built-in FCC/EN55022 Class B Filter
● 4:1 Wide Input Voltage Range
● Six Sided Shielded Enclosure
● Compact 40.6x25.4x11.7mm Package
● Efficiency to >89%
● 2kVDC Isolation
● Fully Protected
● Low Quiescent Current
Description
The RPP20-W series 4:1 input range DC/DC converters are ideal for high end industrial applications and COTS
Military applications where a high ambient operating temperature converter is required.
Although the case size is compact, the converter contains a built-in EN55022 Class B / FCC Level B EMC filter
without the need for any external components.
Selection Guide 24V and 48V 4:1 Input Types
Part Number
Input
Range
VDC
Output
Voltage
VDC
Output
Current
mA
RPP20-243.3SW 9-36
3.3
6000
RPP20-2405SW 9-36
5
4000
RPP20-2412SW 9-36
12
1666
RPP20-2415SW 9-36
15
1333
RPP20-483.3SW 18-75
3.3
6000
RPP20-4805SW 18-75
5
4000
RPP20-4812SW 18-75
12
1666
RPP20-4815SW 18-75
15
1333
RPP20-2405DW 9-36
±5
±2000
RPP20-2412DW 9-36
±12
±833
RPP20-2415DW 9-36
±15
RPP20-4805DW 18-75
±5
±666
±2000
RPP20-4812DW 18-75
±12
±833
RPP20-4815DW 18-75
±15
±666
Input(1)
Current
mA
59/955
65/946
23/946
25/931
28/465
33/465
13/470
12/466
23/946
28/930
24/946
13/470
16/472
13/466
Efficiency(2) Max(3)
Operating
Temp
87.2% 93°C
88.1% 95°C
88.1% 95°C
89.5% 97°C
89.6% 97°C
89.6% 97°C
88.6% 96°C
89.3% 97°C
88.1% 95°C
89.6% 97°C
88.0% 95°C
88.6% 96°C
88.2% 95°C
89.4% 97°C
POWERLINE+
DC/DC-Converter
20 Watt
Single &
Dual Output
UL-60950-1 Pending
RPP20-W
Derating Graph (Ambient Temperature)
RPP20-2405SW
Derating graphs are valid
only for the shown part
number. Please contact
Technical Support for more
information:
info@recom-development.at
www.recom-international.com
REV:2/2009
* ICE Technology
ICE (Innovation in Converter Excellence)
uses state-of-the-art techniques to
minimise internal power dissipation and
to increase the internal temperature
limits to extend the ambient operating
temperature range to the maximum.
Refer to end of section for more details.
Refer to Application Notes
PP-5