Features
Regulated
Converters
• 4:1 Wide Input Voltage Range
• 1.5kVDC / 1 min. Isolation
• UL/IEC/EN60950 Certified & EN50155 Compliant
• Efficiency up to 93.3%
• OVP, OCP & OTP
• +105°C max Case Temperature
DC/DC Converter
RPA60-FW
Description
The RPA60-FW series are high power density, wide input voltage range 60W DC/DC convert-
ers in an industry standard 2”x1” case size. Despite their small size, the RPA60-FW converters are
fully specified devices with output currents up to 12Amps, up to 93% efficiency, no minimum load,
UVLO, 1500VDC / 1 minute isolation, tight regulation and low ripple/noise figures. The trimmable out-
puts are also fully protected against over-temperature, short circuits, overcurrent and overvoltage. The
converters are UL/IEC/EN60950 certified and EN50155 compliant and will find many uses in railway
and industrial applications where board space is at a premium.
60 Watt
2“x1“
33 YEAR
warranty
Single Output
Selection Guide
Part Number
RPA60-2405SFW(2,3)
RPA60-2412SFW(2,3)
RPA60-2415SFW(2,3)
RPA60-2424SFW(2,3)
Input
Voltage Range
[VDC]
9-36
9-36
9-36
9-36
Output
Voltage
[VDC]
05
12
15
24
Output
Current
[mA]
12000
5000
4000
2500
Input(1)
Current
[mA]
2700
2695
2680
2688
Efficiency(1)
typ.
[%]
92.4
92.8
93.3
93
Notes:
Note1: Efficiency is tested by nominal Vin, full load and at 25°C.
Max. Capacitive
Load
[µF]
20000
6000
4000
2000
Model Numbering
RPA60-__ __ SFW/_ _
Input Voltage
Output Voltage
Single
Package(3)
CTRL Logic(2)
Ordering Examples
RPA60-2405SFW = 24V Input, 5V Output, Single, no CTRL pin
RPA60-2405SFW/P = 24V Input, 5V Output, Single, Pos. CTRL function
RPA60-2415SFW/N-HC = 24V Input, 15V Output, Single, Neg. CTRL function, Heat-sink assembled
UL60950-1 Certified
IEC/EN60950 Certified
EN50155 Compliant
E224736
Notes:
Note2: part without suffixes is without CTRL pin, trim pin fitted
add suffix “P” for positive CTRL function (1=ON, 0=OFF), trim pin fitted
add suffix “N” for negative CTRL function (0=ON, 1=OFF), trim pin fitted
Note3: add suffix “-HC” for glued Heat-sink (compatible with all other suffixes)
www.recom-power.com