English
Language : 

RP90Q-RW Datasheet, PDF (1/15 Pages) Recom International Power – 4:1 Wide Input Range
Features
Regulated
Converters
• 4:1 Wide Input Range
• 3kVAC Reinforced Insulation for 110Vin
2.25kVDC Basic Insulation for 24Vin & 48Vin
• Efficiency up to 90%
• No Minimum Load Required
• EN50155 Certified
• IEC/EN60950-1 Certified
DC/DC Converter
RP90Q-RW
Description
The quarter-brick RP90Q series DC/DC converters are designed for railway rolling stock and high voltage battery
applications. Each series has three 4:1 input voltage range options to cover all input voltages from 9VDC up to
160VDC with isolated and regulated 5V to 48VDC outputs. The converters have high efficiencies and metal base-
plates to permit a wide operating temperature range from -40°C to +85°C (when mounted on a suitable heatsink).
The case is fitted with threaded inserts to allow secure mounting to the PCB or bulkhead for use in high shock and
vibration environments. The converters are EN50155 and IEC/EN60950 certified. The RP90Q-RW series have a
three year warranty.
90 Watt
Quarter
33 YEAR
warranty
Brick
Single Output
Selection Guide
Part Number
Input
Output Output
Voltage Range Voltage Current
[VDC]
[VDC] [mA]
RP90Q-2405SRW(2,3) 9-36
5 18000
RP90Q-2412SRW(2,3) 9-36
12 7500
RP90Q-2415SRW(2,3) 9-36
15 6000
RP90Q-2424SRW(2,3) 9-36
24 3700
RP90Q-2448SRW(2,3) 9-36
48 1800
RP90Q-4805SRW(2,3) 16.5-75
5 18000
RP90Q-4812SRW(2,3) 16.5-75
12 7500
RP90Q-4815SRW(2,3) 16.5-75
15 6000
RP90Q-4824SRW(2,3) 16.5-75
24 3700
RP90Q-4848SRW(2,3) 16.5-75
48 1800
RP90Q-11005SRW(2,3) 40-160
5 17000
RP90Q-11012SRW(2,3) 40-160
12 7000
RP90Q-11015SRW(2,3) 40-160
15 5500
RP90Q-11024SRW(2,3) 40-160
24 3500
RP90Q-11048SRW(2,3) 40-160
48 1800
Input(1)
Current
[mA]
4213
4213
4213
4157
4090
2107
2107
2083
2055
2000
868
858
843
858
882
Output
Power
[W]
90
90
90
89
86.5
90
90
90
89
86.5
85
84
82.5
84
86.5
Efficiency(1) Max. Capacitive
typ.
Load
[%]
[µF]
89
36000
89
6250
89
4000
89
1540
88
380
89
36000
89
6250
90
4000
90
1540
90
380
89
34000
89
5830
89
3670
89
1460
89
380
Notes:
Note1: Efficiency is tested by nominal Vin, full load and at 25°C.
EN50155 Certified
IEC/EN60950-1 Certified
Model Numbering
RP90Q-__ __SRW/_ _
Input Voltage
Output Voltage
Single
Package(3)
CTRL Logic(2)
Ordering Examples
RP90Q-2405SRW/N = 24V Input, 5V Output, Single, Neg. CTRL function
RP90Q-11012SRW/P = 110V Input, 12V Output, Single, Pos. CTRL function
RP90Q-2405SRW/N-HC = 24V Input, 5V Output, Single, Neg. CTRL function, with premounted Heat-sink
Notes:
Note2: standard part is with suffix “P” for positive logic (1=ON, 0=OFF)
or add suffix “N” instead for negative logic (0=ON, 1=OFF)
Note3: add suffix “-HC” for premounted Heat-sink
(compatible with all other suffixes)
www.recom-power.com
REV.: 2/2016
PB-1