English
Language : 

RP30-2418SEW Datasheet, PDF (1/3 Pages) Recom International Power – POWERLINE - DC/DC - CONVERTER
POWERLINE - DC/DC-Converter
EW-Ser. 30W, 1.6 kV Isolation, 4:1 Wide Input Range (Single Output)
Features
● Output Current up to 8A
● 30 Watts max. Output Power
● 4:1 Wide Input Voltage Range
● Six-Sided Continuous Shield
● High Efficiency up to 88%
● Standard Package,
50.8 mm x 25.4 mm x 10.2 mm
● Fixed Switching Frequency
Selection Guide 1.8V, 2.5V, 3.3V, 5V, 12V and 15V Input Types
Part Number
Input
Range
Output
Voltage
(VDC)
(VDC)
RP30-241.8SEW
10-40
1.8
RP30-242.5SEW
10-40
2.5
RP30-243.3SEW
10-40
3.3
RP30-2405SEW
10-40
5
RP30-2412SEW
10-40
12
RP30-2415SEW
10-40
15
RP30-481.8SEW
18-75
1.8
RP30-482.5EW
18-75
2.5
RP30-483.3SEW
18-75
3.3
RP30-4805SEW
18-75
5
RP30-4812SEW
18-75
12
RP30-4815SEW
18-75
15
Output
Current
(mA)
8000
8000
6000
6000
2500
2000
8000
8000
6000
6000
2500
2000
Input Current
(see note 5)
(mA)
789
1068
1006
1506
1506
1488
390
527
497
744
753
744
Efficiency
(see note 6)
(%)
80
82
86
87
87
88
81
83
87
88
87
88
Max.
Capacitive
Load
(µF)
65000
33000
19500
10200
3300
1100
65000
33000
19500
10200
3300
1100
RP30-243.3SEW: Derating and Efficiency Curves, External Output Trimming
Derating Curve without Heat-Sink
125
100
75
50
Natural Convection
25
0
-40 -25 -10 0 50 60 70 80 90 100
Ambient Temperature Range (°C)
Efficiency vs Input Voltage
88
87
86
85
84
83
82
81
80
79
78
77
10 15 20 25 30 35 40
Input Voltage (V)
Derating Curve with Heat-Sink
125
100
75
50
Natural Convection
25
0
-40 -25 -10 0 50 60 70 80 90 100
Ambient Temperature Range (°C)
Efficiency vs Output Load
88
87
86
85
84
83
82
81
80
75
70
65
1
2
3
4
5
6
Output Load (A)
External Output Trimming
7
Trim
Up
8
Trim
Down
6
PO 60
August 2002
www.recom-international.com