English
Language : 

RP30-121.5SE Datasheet, PDF (1/4 Pages) Recom International Power – 20 Watt Single & Dual Output
Features
● 2:1 Wide Input Voltage Range
● 30 Watts Output Power
● 1.6kVDC Isolation
● Fixed Operating Frequency
● Six-Sided Continuous Shield
● International Safety Standard Approvals
● UL 1950 Component Recognized
● Standard 50.8 x40.6x10.2mm Package
● Efficiency to 90%
POWERLINE
DC/DC-Converter
RP30-
S_DE
Series
Selection Guide 12V, 24V and 48V Input Types
Part Number
RP30-121.5SE
RP30-121.8SE
RP30-122.5SE
RP30-123.3SE
RP30-1205SE
RP30-1212SE
RP30-1215SE
RP30-241.5SE
RP30-241.8SE
RP30-242.5SE
RP30-243.3SE
RP30-2405SE
RP30-2412SE
RP30-2415SE
RP30-481.5SE
RP30-481.8SE
RP30-482.5SE
RP30-483.3SE
RP30-4805SE
RP30-4812SE
RP30-4815SE
RP30-1212DE
RP30-1215DE
RP30-2412DE
RP30-2415DE
RP30-4812DE
RP30-4815DE
Input
Range
VDC
9-18
9-18
9-18
9-18
9-18
9-18
9-18
18-36
18-36
18-36
18-36
18-36
18-36
18-36
36-75
36-75
36-75
36-75
36-75
36-75
36-75
9-18
9-18
18-36
18-36
36-75
36-75
Output
Voltage
VDC
1.5
1.8
2.5
3.3
5
12
15
1.5
1.8
2.5
3.3
5
12
15
1.5
1.8
2.5
3.3
5
12
15
±12
±15
±12
±15
±12
±15
Output
Current
mA
6000
6000
6000
6000
6000
2500
2000
6000
6000
6000
6000
6000
2500
2000
6000
6000
6000
6000
6000
2500
2000
±1250
±1000
±1250
±1000
±1250
±1000
Input (4)
Current
mA
1014
1169
1582
2037
3012
2976
2976
493
580
780
1010
1490
1470
1470
244
290
390
500
740
730
730
3012
3012
1488
1488
744
744
Efficiency(5)
%
78
81
83
85
87
88
88
80
82
84
86
88
89
89
81
83
85
87
89
90
90
87
87
88
88
88
88
Capacitive(6)
Load max.
µF
85800
65000
33000
19500
10200
3240
1100
85800
65000
33000
19500
10200
3300
1100
85800
65000
33000
19500
10200
3300
1100
±1020
±675
±1020
±675
±1020
±675
30 Watt
Single &
Dual
Output
Description
The E-Series of DC/DC Converters are fully certified to EN 60950: 2000. This makes them ideal for all
Telecom and safety applications where approved isolation is required.
They also meet UL 1950 and CSA 950 standards.
240
April-2005
www.recom-international.com