English
Language : 

RP120Q-RW Datasheet, PDF (1/15 Pages) Recom International Power – 4:1 Wide Input Range
Features
Regulated
Converters
• 4:1 Wide Input Range
• 3kVAC Reinforced Insulation for 110Vin
2.25kVDC Basic Insulation for 24Vin & 48Vin
• Efficiency up to 90%
• No Minimum Load Required
• EN50155 Certified
• IEC/EN60950-1 Certified
DC/DC Converter
RP120Q-RW
Description
The quarter-brick RP120Q series DC/DC converters are designed for railway rolling stock and high voltage battery
applications. Each series has three 4:1 input voltage range options to cover all input voltages from 9VDC up to
160VDC with isolated and regulated 5V to 48VDC outputs. The converters have high efficiencies and metal base-
plates to permit a wide operating temperature range from -40°C to +85°C (when mounted on a suitable heatsink).
The case is fitted with threaded inserts to allow secure mounting to the PCB or bulkhead for use in high shock and
vibration environments. The converters are EN50155 and IEC/EN60950 certified. The RP120Q-RW series have a
three year warranty.
120 Watt
Quarter
33 YEAR
warranty
Brick
Single Output
Selection Guide
Part Number
Input
Output Output
Voltage Range Voltage Current
[VDC]
[VDC] [mA]
RP120Q-2405SRW 9-36
5 24000
RP120Q-2412SRW 9-36
12 10000
RP120Q-2415SRW 9-36
15 8000
RP120Q-2424SRW 9-36
24 5000
RP120Q-2448SRW 9-36
48 2500
RP120Q-4805SRW 16.5-75
5 24000
RP120Q-4812SRW 16.5-75
12 10000
RP120Q-4815SRW 16.5-75
15 8000
RP120Q-4824SRW 16.5-75
24 5000
RP120Q-4848SRW 16.5-75
48 2500
RP120Q-11005SRW 40-160
5 24000
RP120Q-11012SRW 40-160
12 11000
RP120Q-11015SRW 40-160
15 8600
RP120Q-11024SRW 40-160
24 5500
RP120Q-11048SRW 40-160
48 2700
Input
Current
[mA]
5618
5682
5618
5682
5682
2809
2809
2777
2777
2777
1225
1363
1317
1348
1323
Output
Power
[W]
120
120
120
120
120
120
120
120
120
120
120
132
130
132
130
Efficiency(1) Max. Capacitive
typ.
Load
[%]
[µF]
89
48000
88
8300
89
5300
88
2100
88
520
89
48000
89
8300
90
5300
90
2100
90
520
89
48000
88
9170
89
5730
89
2290
89
560
Notes:
Note1: Efficiency is tested by nominal Vin, full load and at 25°C.
EN50155 Certified
IEC/EN60950-1 Certified
Model Numbering
RP120Q-__ __SRW/_ _
Input Voltage
Output Voltage
Single
Package(3)
CTRL Logic(2)
Ordering Examples
RP120Q-2405SRW/N = 24V Input, 5V Output, Single, Neg. CTRL function
RP120Q-11012SRW/P = 110V Input, 12V Output, Single, Pos. CTRL function
RP120Q-2405SRW/N-HC = 24V Input, 5V Output, Single, Neg. CTRL function, with premounted Heat-sink
Notes:
Note2: standard part is with suffix “P” for positive logic (1=ON, 0=OFF)
or add suffix “N” instead for negative logic (0=ON, 1=OFF)
Note3: add suffix “-HC” for premounted Heat-sink
(compatible with all other suffixes)
www.recom-power.com
REV.: 2/2016
PB-1