Features
● Single Outputs up to 30A
● Input/Output 1.6kVDC Isolation
● Adjustable Output Voltage
● No Minimum Load
● Under -Voltage Lockout
● Industry Standard Footprint
● Fixed Operating Frequency
● Halt Tested
● Compact 36.83 x 57.91 x 12.7mm Package
● High Efficiency to 90%
Selection Guide
Part
Number
Single Output
RP100-481.8SB
RP100-482.5SB
RP100-483.3SB
RP100-4805SB
Input
Voltage
(VDC)
36 – 75
36 – 75
36 – 75
36 – 75
Output
Voltage
(VDC)
1.8
2.5
3.3
5.0
Output
Current
(A)
30
30
25
20
Add suffix “P” for positive logic ON/OFF control.
Load
Regulation
(mV)
5.4
7.5
10
15
Efficiency (5)
%
85
87
89
90
INNOLINE
DC/DC-Converter
RP100-SB
Series
100 Watt
Single
Output
Description
The RP100-SB Series has been specifically designed for low voltage silicon applications. A wide input
voltage range, output voltage trim and sense inputs are all standard features. The converters also bene-
fit from comprehensive over-current, over-voltage and over-temperature protection.
The RP100-SB is ideally suited to telecom, network and industrial applications.
Notes:
1. Maximum output deviation is 10% inclusive of remote sense. If remote sense is not being used,
the +Vsense should be connected to its corresponding +Vout
2. Standard is negative remote ON/OFF, add suffix“P” for positive remote ON/OFF.
3. Heat sink is optional and P/N: 7G-0021, 7G-0022, 7G-0023, 7G-0024.
4. The RP100-SB meets level A and level B conducted emissions only with external components connected before
the input pin to the converter.
5. Typical value at nominal input voltage and full load.
6. BASEPLATE GROUNDING : Base-plate should be grounded at one of the four screw bolts prior to operation.
www.recom-international.com