English
Language : 

RN Datasheet, PDF (1/3 Pages) Recom International Power – 1.25 Watt DIP8 Sigle Output
Features
Unregulated
Converters
● Custom Solutions Available
● 1kVDC & 2kVDC Isolation
● No Extern. Components Required
● UL94V-0 Package Material
● No Heatsink Required
● Efficiency to 85%
ECONOLINE
DC/DC-Converter
RN
Series
Selection Guide
Part
Number
DIP 8
(2kV)
RN-xx3.3S (H)
RN-xx05S (H)
RN-xx07S (H)
RN-xx09S (H)
RN-xx12S (H)
RN-xx15S (H)
RN-xx24S (H)
xx = Input Voltage
Input
Voltage
(VDC)
3.3, 5, 9, 12, 15, 24
3.3, 5, 9, 12, 15, 24
3.3, 5, 9, 12, 15, 24
3.3, 5, 9, 12, 15, 24
3.3, 5, 9, 12, 15, 24
3.3, 5, 9, 12, 15, 24
3.3, 5, 9, 12, 15, 24
Output
Voltage
(VDC)
3.3
5
7
9
12
15
24
Output
Current
(mA)
378
250
180
140
104
84
52
Efficiency
(%)
70
70-72
72-75
75-80
79-82
80-84
80-85
1.25 Watt
DIP8
Single Output
Specifications (Core Operating Area)
Input Voltage Range
±10%
Output Voltage Accuracy
±5%
Line Voltage Regulation
Load Voltage Regulation
(10% to 100% full load)
3.3V output types
5V output type
9V, 12V, 15V, 24V output types
1.2%/1% of Vin max.
20% max.
15% max.
10% max.
Output Ripple and Noise (20MHz limited)
75mVp-p max.
Operating Frequency
50kHz min. / 100kHz typ. / 105kHz max.
Efficiency at Full Load
No Load Power Consumption
70% min. / 75% typ.
106mW min. / 153mW typ. / 210mW max.
Isolation Voltage
Rated Working Voltage
(tested for 1 second)
(long term isolation)
1.000VDC min.
see Application Notes
Isolation Voltage
Rated Working Voltage
Isolation Capacitance
Isolation Resistance
Short Circuit Protection
H-Suffix
H-Suffix
(tested for 1 second)
(long term isolation)
2.000VDC min.
see Application Notes
30pF min. / 95pF max.
10 GΩ min.
1 Second
Operating Temperature Range (free air convection)
-40°C to +85°C (see Graph)
Storage Temperature Range
-55°C to +125°C
Relative Humidity
MSL Level 1
95% RH
Package Weight
} MTBF (+25°C) Detailed Information see
using MIL-HDBK 217F
(+85°C) Application Notes chapter "MTBF" using MIL-HDBK 217F
1.9g
955 x 103 hours
132 x 103 hours
www.recom-international.com
April-2005
Derating-Graph
(Ambient Temperature)
100
80
60 Safe Operating Area
40
30
20
0
-40
0
50
100 150
85
Operating Temperature °C
57