English
Language : 

RK-H6 Datasheet, PDF (1/4 Pages) Recom International Power – high 6.4kVDC Isolation
Features
Unregulated
Converters
• high 6.4kVDC Isolation
• wide Operating Temperature Range from -40°C to +90°C
without derating
• high capacitive load capability
• Continuous Short Circuit Protection
• Built-in EN55022 Class A Filter
• Efficiency up to 80%
DC/DC Converter
RK/H6 & RH/H6
Description
The RK/H6 and RH/H6 series 1W DC/DC converters feature high 6.4kVDC isolation and an extended
operating temperature range up to +90°C without derating, yet are lower cost than standard high
isolation converters. They are suitable for demanding industrial and high isolation test and measurement
applications.
1 Watt
SIP7
33 YEAR
warranty
Single and Dual
Output
Selection Guide
Part
Number
RK-xx3.3S/H6
RK-xx05S/H6
RK-xx12S/H6
RK-xx15S/H6
RH-xx3.3D/H6
RH-xx05D/H6
RH-xx12D/H6
RH-xx15D/H6
Input
Voltage Range
(VDC)
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
Output
Voltage
(VDC)
3.3
5
12
15
±3.3
±5
±12
±15
Output
Current
(mA)
303
200
84
66
±152
±100
±42
±33
Efficiency
typ.
(%)
71-74
74-77
77-79
77-80
73-74
74-77
77-80
78-80
max. Capacitive
Load (1)
(µF)
1000
1000
220
220
±330
±330
±100
±100
Notes:
Note1: Max. capacitive load is tested at nominal input voltage and full load.
E224736
UL60950-1 Certified
CSA C22.2 No. 60950-1-07 Certified
IEC60950-1 Certified
IEC62368-1 Certified
Specifications (measured at TA= 25°C, nominal input voltage, full load and after warm up unless otherwise specified)
BASIC CHARACTERISTICS
Parameter
Condition
Input Voltage Range
Start-up Time
Vin nominal, full load
Operating Frequency
Vin nominal, full load
Minimum Load
Output Ripple and Noise
Vin nominal, 20MHz BW limited
Min.
Typ.
Max.
±10%
20ms
80kHz
0%
60mVp-p 120mVp-p
continued on next page
www.recom-power.com
REV.: 2/2016
ECO-1