English
Language : 

RJZ-RGZ Datasheet, PDF (1/3 Pages) Recom International Power – Optional Continuous Short Circuit Protected
Features
Unregulated
Converters
● 2W Single and Dual Outputs in DIP 14
● 3kVDC or 4kVDC Isolation
● Optional Continuous Short Circuit Protected
● Custom Solutions Available
● UL94V-0 Package Material
● Efficiency up to 85 %
● Suitable for IGBT Applications
Description
The RJZ and RGZ series converters are available in DIP14 packages, so can be used for
applications where component height is restricted. The wide selection of input voltage and
output voltage options plus an I/O-Isolation of 3kVDC or 4kVDC as standard makes these
converters suitable for many industrial, medical and IGBT applications.
Selection Guide
Part
Input
Output
Output Efficiency
Number
Voltage
Voltage Current
DIP 14
4kV
(VDC)
(VDC)
(mA)
(%)
RJZ-xx3.3S* (H) 3.3,5,9,12,15,24
3.3
606
70-75
RJZ-xx05S* (H) 3.3,5,9,12,15,24
5
400
78-85
RJZ-xx09S* (H) 3.3,5,9,12,15,24
9
222
78-84
RJZ-xx12S* (H) 3.3,5,9,12,15,24
12
166
80-85
RJZ-xx15S* (H) 3.3,5,9,12,15,24
15
133
82-85
RJZ-xx24S* (H) 3.3,5,9,12,15,24
24
83
80-85
RGZ-xx3.3D* (H) 3.3,5,9,12,15,24
±3.3
±303
75
RGZ-xx05D* (H) 3.3,5,9,12,15,24
±5
±200
75-82
RGZ-xx09D* (H) 3.3,5,9,12,15,24
±9
±111
75-80
RGZ-xx12D* (H) 3.3,5,9,12,15,24
±12
±84
78-82
RGZ-xx15D* (H) 3.3,5,9,12,15,24
±15
±66
80-84
RGZ-xx24D* (H) 3.3,5,9,12,15,24
±24
±42
82-84
RGZ-xx1509D* (H)
5, 12, 24
+15/-9 +67/-111 70-81
xx = Input Voltage. Other input and output voltage combinations available on request.
* add Suffix “P” for Continuous Short Circuit Protection, e.g. RGZ-0524D/P, RJZ-0505S/HP
Max
Capacitive
Load(1)
3300µF
1200µF
1200µF
680µF
680µF
220µF
±1500µF
±470µF
±470µF
±220µF
±220µF
±100µF
±330µF
Specifications (measured at TA = 25°C, nominal input voltage, full load and after warm-up)
Input Voltage Range
±10%
Output Voltage Accuracy
±5%
Line Voltage Regulation
1.2%/1% of Vin typ.
Load Voltage Regulation
3.3V Types
±20% max.
(10% to 100% full load)
5V Types
±15% max.
All other Types, RGZ-xx1509D
±10% max.
Output Ripple and Noise (20MHz limited)
±150mVp-p max.
Temperature Coefficient
0.02%/°C max.
Operating Frequency
20kHz min. / 50kHz typ. / 90kHz max.
RGZ-xx1509D
20kHz min. / 45kHz typ.
Efficiency at Full Load
70% min. / 80% typ.
Minimum Load = 0%
Specifications valid for 10% minimum load only.
Isolation Voltage
(tested for 1 second)
3000VDC
(rated for 1 minute)
1500VAC / 60Hz
Isolation Voltage
H-Suffix
(tested for 1 second)
4000VDC min.
H-Suffix)
(rated for 1 minute)
2000VAC / 60Hz
Isolation Capacitance
120pF max.
Isolation Resistance
15GΩ min.
Short Circuit Protection
1 Second
P-Suffix
Continuous
Operating Temperature Range (free air convection, without derating)
-40°C to +90°C (see Graph)
Case Temperature
110°C max.
continued on next page
E-106
REV: 0/2015
ECONOLINE
DC/DC-Converter
with 3 year Warranty
2 Watt
DIP14
Single & Dual
Output
RoHS
2011/65/EU
6/6
EN-60950-1 Certified
IEC/EN-60601-1 Certified*
* +15/-9 Version excluded
RJZ_RGZ
Derating-Graph
(Ambient Temperature)
100
80
60 Safe Operating Area
40
20
0
-40
0
50 90 100 150
95
Operating Temperature °C
**Any data referred to in this datasheet are of indicative nature
and based on our practical experience only. For further details,
please refer to our Application Notes.
Refer to Application Notes