English
Language : 

REC15-M Datasheet, PDF (1/2 Pages) Recom International Power – 15 Watt Single & Dual Output
Features
Regulated
Converters
● 15W in 2” x 1” Package
● 2kVDC and 3kVDC Isolation Options
● 2:1 or 4:1 Input Voltage Range
● Continuous Short Circuit Protection
(power limiting)
● Synchronous Rectification on 3.4V & 5.1V outputs
● Full SMD internal design
● Remote Control Pin
● Efficiency to 87%
Description
The REC15-xxxxS_D/M -series offer single and dual regulated outputs in a 2”x1” package with
2kVDC or 3kVDC isolation options and are suitable for higher power industrial applications. Re-
mote on/off control is standard. The converters can deliver 150% rated power for short periods
of time to cope with applications with large capacitive loads or high start up currents. The out-
puts with 3A load current have raised output voltages to compensate for track losses as stan-
dard.
Selection Guide
Part
Number
Input
Voltage
(VDC)
Output
Voltage
(VDC)
Output
Current
(mA)
Efficiency Max. Cap.
(typ.) Load
(%)
ECONOLINE
DC/DC-Converter
with 3 year Warranty
15 Watt
2” x 1”
Single & Dual
Output
REC15-xx3.4S/H*/M
9-18, 18-36, 36-75 3.4
3000
84-85 3300µF
REC15-xx5.1S/H*/M
9-18, 18-36, 36-75 5.1
3000
86-87 3300µF
REC15-xx12S/H*/M
9-18, 18-36, 36-75 12
1250 85-86 3300µF
REC15-xx15S/H*/M
9-18, 18-36, 36-75 15
1000 85-86 3300µF
REC15-xx05D/H*/M
9-18, 18-36, 36-75 ±5 ±1500 82-83 ±1500µF
REC15-xx12D/H*/M
REC15-xx15D/H*/M
REC15-xx3.4SZ/H*/M
9-18, 18-36, 36-75 ±12
9-18, 18-36, 36-75 ±15
9-36, 18-75
3.4
±625
±500
3000
85-86
85-86
84-85
±1000µF
±1000µF
3300µF
RoHS
2011/65/EU
6/6
E-224736
REC15-xx5.1SZ/H*/M
REC15-xx12SZ/H*/M
REC15-xx15SZ/H*/M
9-36, 18-75
9-36, 18-75
9-36, 18-75
5.1
3000
12
1250
15
1000
87 3300µF
86 3300µF
86 3300µF
EN-60950-1 Certified
EN-60601-1 Certified
UL-60950-1 Certified
REC15-xx05DZ/H*/M
REC15-xx12DZ/H*/M
9-36, 18-75
9-36, 18-75
±5 ±1500
±12 ±625
83 ±1500µF
86 ±1000µF
REC15/M
REC15-xx15DZ/H*/M
9-36, 18-75
±15 ±500
86 ±1000µF
* Standard is /H2 for 2kVDC isolation,
use /H3 for 3kVDC Isolation
2:1
xx = 9-18Vin = 12,
xx = 18-36Vin = 24,
xx = 36-75Vin = 48
4:1
xx = 9-36Vin = 24,
xx = 18-75Vin = 48
Specifications (measured at TA = 25°C, nominal input voltage, full load and after warm-up)
Input Voltage Range
Input Filter
Output Voltage Accuracy (the Output 3.4V is ±1.2% max.)
Line Voltage Regulation
Load Voltage Regulation
Single
(25% to 100% full load )
Dual
Cross Regulation (100%: 25% to 100% full load )
Output Ripple and Noise (with 100n output capacitor and 20MHz BW)
Start-up time (Nom. Vin at 100% Load)
Operating Frequency (Full Load)
Efficiency (Nom. Vin at 100% Load)
Minimum Load
Input Surge Voltage (100ms max.)
12V Input
24V Input
48V Input
2:1 or 4:1
PI Network
±1.0% max.
±0.3% max.
±0.5% max.
±1.2% max.
±5% max.
100mVp-p max.
25ms typ.
300kHz typ.
see Selection Guide
0%
36VDC
50VDC
100VDC
continued on next page
**Any data referred to in this datasheet are of indicative nature
and based on our practical experience only. For further details,
please refer to our Application Notes.
Refer to Application Notes
E-168
REV: 0/2015
www.recom-power.com