Features
Regulated
Converters
● 1.5W/1.8W in Mini DIP and SMD Packages
● 1KVDC Isolation
● Regulated Output
● UL94V-0 Package Material
● Continuous Short Circuit Protection
● Internal SMD design
● 100% Burned In
● Efficiency to 70%
Selection Guide
Part
Input
Output
Number
Voltage
Voltage
DIP24 miniature (/SMD)
(VDC)
(VDC)
REC1.5-xx3.3SR/H1
5, 12, 24
3.3
REC1.5-xx05SR/H1
5, 12, 24
5
REC1.5-xx09SR/H1
5, 12, 24
9
REC1.5-xx12SR/H1
5, 12, 24
12
REC1.5-xx15SR/H1
5, 12, 24
15
REC1.8-xx3.3SR/H1
5, 12, 24
3.3
REC1.8-xx05SR/H1
5, 12, 24
5
REC1.8-xx09SR/H1
5, 12, 24
9
REC1.8-xx12SR/H1
5, 12, 24
12
REC1.8-xx15SR/H1
5, 12, 24
15
* add suffix "/SMD" for SMD package, e.g. REC1.5-0505SR/H1/SMD
* add suffix “/M“for Metal Case, e.g. REC1.5-0505SR/H1/M
Specifications (Core Operating Area)
Output
Current
(mA)
450
300
166
125
100
500
360
200
150
120
Input Voltage Range
±15% max
Output Voltage Accuracy
±3% max.
Line Voltage Regulation
±0.4% max
Load Voltage Regulation (10% to 100% full load )
±0.8% max.
Output Ripple and Noise (at 20MHz BW)
100mVp-p max.
Operating Frequency
85kHz min.
Efficiency
65% min.
No Load Power Consumption
200mW max.
Isolation Voltage
Rated Working Voltage
(tested for 1 second)
(long term isolation)
1000VDC min.
see Application Notes
Isolation Capacitance
Isolation Resistance
Short Circuit Protection
20pF min. / 60pF max.
1 GΩ min.
Continuous
Short Circuit Protection
-40°C to +80°C (see Graph)
Storage Temperature Range
-50°C to +125°C
Temperature Coefficient
±0.02%/°C
Relative Humidity
95% RH
Thermal Impedance
Natural convection 20°C/W for metal case
Package Weight
} MTBF (+25°C)
(+80°C)
Detailed information see
Application Notes chapter “MTBF”
using MIL-HDBK 217F
using MIL-HDBK 217F
8.5g
1000 x 103 hours
150 x 103 hours
62
July-2006
ECONOLINE
DC/DC-Converter
REC1.5- &
REC1.8-
SR/H1
Series
1.5/1.8 Watt
DIP24 minia-
ture & SMD
Single Output
Derating-Graph
(Ambient Temperature)
100
80
60
Safe Operating Area
40
25
20
0
-40
0
50 80 100 150
Operating Temperature °C