English
Language : 

RD-123.3D Datasheet, PDF (1/3 Pages) Recom International Power – 2 Watt SIP7 & DIP14 Dual Output
Features
Unregulated
Converters
● Dual Output from a Single Input Rail
● 1kVDC & 2kVDC Isolation
● Power Sharing on Output
● Custom Solutions Available
● UL94V-0 Package Material
● Efficiency to 86%
ECONOLINE
DC/DC-Converter
RD & RC
Series
Selection Guide
Part
Number
SIP 7
DIP 14 2kV
RD-xx3.3D RC-xx3.3D (H)
RD-xx05D RC-xx05D (H)
RD-xx09D RC-xx09D (H)
RD-xx12D RC-xx12D (H)
RD-xx15D RC-xx15D (H)
RD-xx24D RC-xx24D (H)
xx = Input Voltage
Input
Voltage
(VDC)
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
Output
Voltage
(VDC)
±3.3
±5
±9
±12
±15
±24
Output
Current
(mA)
±303
±200
±111
±84
±66
±42
Efficiency
(%)
70
70-82
80-84
80-84
82-86
82-86
2 Watt
SIP7 & DIP14
Dual Output
Specifications (Core Operating Area)
Input Voltage Range
±10%
Output Voltage Accuracy
±5%
Line Voltage Regulation
Load Voltage Regulation
(10% to 100% full load)
3.3V output types
5V output type
9V, 12V, 15V, 24V output types
1.2%/1% of Vin max.
20% max.
15% max.
10% max.
Output Ripple and Noise (20MHz limited)
150mVp-p max.
Operating Frequency
34kHz min. / 50kHz typ. / 85kHz max.
Efficiency at Full Load
70% min. / 80% typ.
No Load Power Consumption
163mW min. / 223mW typ. / 350mW max.
Isolation Voltage
Rated Working Voltage
(tested for 1 second)
(long term isolation)
1.000VDC min.
see Application Notes.
Isolation Voltage
Rated Working Voltage
H-Suffix
H-Suffix
(tested for 1 second)
(long term isolation)
2.000VDC min.
see Application Notes
Isolation Capacitance
40pF min. / 115pF max.
Isolation Resistance
10 GΩ min.
Short Circuit Protection
1 Second
Operating Temperature Range (free air convection)
-40°C to +85°C (see Graph)
Storage Temperature Range
-55°C to +125°C
Relative Humidity
MSL Level 1
95% RH
Package Weight
2.8g
} MTBF (+25°C) Detailed Information see
using MIL-HDBK 217F
(+85°C) Application Notes chapter "MTBF" using MIL-HDBK 217F
988 x 103 hours
135 x 103 hours
www.recom-international.com
April-2005
Derating-Graph
(Ambient Temperature)
100
80
60 Safe Operating Area
40
20
0
-40
0
50
100 150
85
Operating Temperature °C
65