English
Language : 

RAZ-0505S Datasheet, PDF (1/2 Pages) Recom International Power – 25°C, nominal input voltage and rated output current unless otherwise specified
Features
Regulated
Converters
● 1:1 Input Range
● Efficiency up to 69%
● 1kVDC and 2kVDC Isolation Option
● 1W SMD Package
● -40°C to +85°C Operating Temperature Range
● Continuous Short Circuit Protection
Selection Guide
Part
Number
SMD
Input
Voltage
(VDC)
Output
Voltage
(VDC)
Output
Current
(mA)
Efficiency
(typ.)
RAZ-0505S*
5
5
200
67%
RAZ-1205S*
12
5
200
68%
RAZ-2405S*
24
5
200
69%
* add Suffix “/H“ for 2kVDC/1min. Isolation - e.g. RAZ-0505S/H
* add Suffix “-R“ for tape & reel packing - e.g. RAZ-1205S-R, RAZ-2405S/H-R
Capacitive
Load
(max.)
2200µF
2200µF
2200µF
ECONOLINE
DC/DC-Converter
1 Watt SMD
Single Output
Specifications (measured at TA = 25°C, nominal input voltage and rated output current unless otherwise specified
Input Voltage Range
±10% max.
Output Voltage Accuracy
Line Voltage Regulation
-1% typ., ±5% max.
(low line to high line at max. load)
1% max.
RoHS
2011/65/EU
6/6
Load Voltage Regulation
(10% to 100% full load)
1% max.
Output Ripple and Noise (20MHz BW)
Operating Frequency (Vin=nominal input)
Efficiency at Full Load
50mVp-p typ., 75mVp-p max.
20kHz min. / 35kHz typ. / 60kHz max.
see Selection Guide
EN-60950-1 Certified
EN-60601-1 Certified*
(*/H suffix)
Minimum Load = 0%
Isolation Voltage
Isolation Voltage
Isolation Capacitance
H-Suffix
H-Suffix
Specifications valid for 10% minimum load only
(tested for 1 minute)
1000 VDC
(tested for 1 second)
1250 VDC
(testet for 1 minute)
2000 VDC
(tested for 1 second)
2500 VDC
6pF typ., 10pF max.
RAZ
Isolation Resistance
(Viso=500V)
Short-Circuit Protection
Operating Temperature Range
Storage Temperature
Relative Humidity
Package Weight
} MTBF (+25°C) Detailed Information see
using MIL-HDBK 217F
MTBF (+85°C) Application Notes chapter "MTBF" using MIL-HDBK 217F
10GΩ min.
continuous
-40°C to +85°C
-55°C to +125°C
95% RH
1.6g
3914 x 10³ hours
855 x 10³ hours
Certifications
EN General Safety
EN60950-1, 2nd Edition
EN Medical Safety Report: MDD1112018 + RM1112018
IEC/EN 60601-1 3rd Edition
Medical Report + ISO14971 Risk Assessment
Note 1: Maximum capacitive load is defined as the capacitive load that will allow start up in under
1 second without damage to the converter.
Derating-Graph
(Ambient Temperature)
100
80
60 Safe Operating Area
40
30
20
0
-40
0
50
100 150
85
Operating Temperature °C 95
Refer to Application Notes
E-62
REV: 0/2013
www.recom-electronic.com