English
Language : 

RACD60 Datasheet, PDF (1/3 Pages) Recom International Power – 60 Watt PFC Single Output
Features
LED DRIVER
● AC-DC LED Power Supply
● 60W Dual Mode CV and CC Output
● Power Factor Corrected
● Universal Input Voltage Ranges
● Low Cost Open Frame Design
● High Efficiency
● Adjustable Current Limit
● Long 5 Year Warranty
LIGHTLINE
AC/DC-Converter
with 5 year Warranty
Description
A compact universal input voltage 60W constant voltage/ constant current switching power
module suitable for driving high power LEDs. The LED drivers have a dual mode of operation:
CV mode: at loads below the preset current limit , the RACD60 behaves as a voltage source.
CC mode: at loads above the preset current limit, the RACD60 behaves as a current source.
Thus the same power supply can be used with both CV and CC LED modules. The current
limit can be set by the user. The RACD 60 series have a universal input voltage range and are
fully protected against output short circuit, overload and over-temperature. The converters
feature built-in power factor correction as standard.
Selection Guide
Part
Number
Input Voltage
Range
(VAC)
Output
Voltage
(VDC)
RACD60-4200* universal 11 min - 13.5 max
Output Current Preset Efficiency Max
Adjust Range Current Limit (230VAC) Power
(mA)
(mA)
(%) (W)
3570 - 4200
4200
85 60W
RACD60-2400* universal 17 min -24 max 1700 - 2500
2400
87 60W
RACD60-2100* universal 21 min - 28 max 1400 - 2140
2100
89 60W
RACD60-1400* universal 21 min - 28 max 1400 - 2140
1400
89 60W
RACD60-1050* universal 33.5 min - 48 max 825 - 1250
1050
89 60W
RACD60-700* universal 38 min - 54 max
700 - 850
700
89 46W
* add suffix /OF for open frame version (Standard) or add suffix /IP67 for potted version
Specifications (typical at 25°C and after warm up time unless otherwise specified )
Input Voltage Range
Rated Power
Input Frequency Range
Power Factor Correction
Input Current (full load)
Inrush Current (cold start)
Leakage Current
Input Fuse
Output Current Accuracy
Output Current Adjust
Line Voltage Regulation
Load Voltage Regulation
Minimum Load Current
Output Ripple and Noise
Operating Frequency
Efficiency at Full Load
Isolation Voltage (60Hz RMS)
Temperature Coefficient
Overload Protection
Short Circuit Protection
Output Overvoltage Protection
22
90-264VAC
60 Watts max.
47-63 Hz
Full Load, 115VAC/230VAC
> 0.9
115VAC/230VAC
0.8A / 0.4A max.
115VAC/230VAC
25A / 50A max.
230VAC/63Hz
<0.75mA max.
Built-in
3.15A Slow Blow
Full load
±5%
Preset Potentiometer
75% to 100% approx.
LL to HL at Full Load
±4% typ.
60% to 100% Load
±5% typ.
see table
20MHz limited,with 0.1µF + 47µF
5Vp-p max.
65kHz typ.
input to output (/OF Version)
input to output (/IP67 Version)
input to filter ground
output to filter ground
see table
3.75kVAC / 1 minute
4kVAC / 1 minute
1500VAC / 1 minute
500VAC / 1 minute
±0.02%/°C typ.
105% typ.
Continuous, Hiccup, Automatic Restart
Zener Diode Clamp
REV: 5/2010
60 Watt PFC
Single
Output
RoHS
2002/95/EC
6/6
UL Pending
EN 61347 Certified
CE Marked
RACD60
Derating Graph
(Ambient Temperature)
125
100
75
50
40
25
Natural Convection
All others
4.2A
0
-25 0 50 60 70 80 90
Ambient Temperature Range (°C)
Please Read Application Notes