English
Language : 

RACD45-A Datasheet, PDF (1/2 Pages) Recom International Power – 45 Watt PFC Single Output
Features
LED DRIVER
● Constant Current Operation
● Suitable for High Brightness LED Products
● Built-In Active PFC Function
● Overvoltage-, Short Circuit- and Over-
temperature Protection
● Built-In 3 in 1 Dimming
● IP67 Rated
● Class 2 Power Unit UL1310
Selection Guide
Part
Number
RACD45-700A
RACD45-1050A
RACD45-1250A
RACD45-1850A
Output
Voltage
(VDC)
57
48
36
24
Rated
Power
(W)
40
48
45
45
Rated
Current
(mA)
70 - 700
105 - 1050
125 - 1250
185 - 1850
Output
Voltage Range
(V)
40 - 57
Efficiency
(typ.)
87%
33 - 48
87%
24 - 36
86%
15 - 24
85%
LIGHTLINE
AC/DC-Converter
with 5 year Warranty
45 Watt PFC
Single
Output
Specifications (measured at 230VAC and 25°C ambient temperature)
Input Voltage Range
90-305 VAC
Input Frequency Range
47-63Hz
Power Factor (Full Load)
120VAC
>0.98
240VAC
>0.93
277VAC
>0.90
THD
Full Load, 115VAC
13% max.
Full Load, 230VAC
19% max.
DC Dimming
Open = 100%
DC 1-10V
PWM Dimming
Open = 100%
Duty 10% - 100%
Freq.
500Hz - 3000Hz
Voltage
Hi=10V, Low=0V
Resistance Dimming
10K - 100K Ω
Current Accuracy
±5%
AC Input Current
100-240VAC
0.6A
277VAC
0.25A
Inrush Current (Cold Start)
240VAC
70A
Leakage Current
<0.5mA / 240VAC
Start-up Time (at Full Load)
<2sec
Isolation Voltage
3.75kVAC / 1 minute
Short Circuit Protection
Hiccup
Over Voltage Protection
24V
26.4 - 31.2V
36V
39.6 - 46.8V
48V
52.8 - 62.4 V
57V
62.7 - 70V
Over Temperature Protection
Latch Mode
105 ± 10°C
Vibration
10-500Hz, 2G, 60Min. along X, Y and Z
Storage Humidity
10% - 90% RH
Operating Humidity
20% - 90% RH Non-Condensing
Weight
420g
Operating Temperature
-30°C to +50°C
Storage Temperature
-40°C to +60°C
Ripple & Noise
24V
200mV
(at 20MHz bandwith using 0.1uF & 47uF capacitor) all others
250mV
IP Rating
IP67
Isolation Resistance
100MΩ / 500VDC at 25°C
Dimension (L*W*H)
179*45.1*32.5mm
continued on next page
L-48
REV: 0/2015
RoHS
2011/65/EU
6/6
E340696
EN 61347-1 Certified
EN 61347-2-13 Certified
UL8750 Certified
RACD45-A
Derating-Graph
(Ambient Temperature)
Load
100%
90%
75%
60%
40%
20%
-30 0 20 50 65
Ambient Temperature (°C)
Note:
All LED Drivers may not be used without a load.
They must be switched on the primary side only.
Noncompliance may damage the LED or reduce
its lifetime.
Refer to Application Notes
www.recom-power.com