English
Language : 

RACD100-A Datasheet, PDF (1/2 Pages) Recom International Power – 100 Watt Single Output
Features
LED DRIVER
● High Output Voltage
● Universal AC Input
● Constant Current Operation
● Active Power Factor Correction
● IP67 Design for Indoor and Outdoor Use
● Compact Size
● Digital PWM and Analogue Voltage Dimming
Selection Guide
Part
Number
RACD100-700A
RACD100-1400A
Nominal
Voltage
(VAC)
100-277
100-277
Rated
Voltage
(V)
142
71
Output Voltage
Range
(VDC)
100-142
50-71
Rated
Current
(mA)
700
1400
Efficiency
typ.
(%)
91
91
Specifications (measured at 240V AC and 25°C ambient temperature)
2/Input Voltage Range
90-305 VAC or 127-430VDC
Input Frequency Range
47-63Hz
Power Factor
Full Load, 115VAC
>0.98
Full Load, 230VAC
>0.94
70% Load
>0.90
DC Dimming
Open = 100%
DC 1-10V
PWM Dimming
Open = 100%
Duty 10% - 100%
Freq.
500Hz - 3000Hz
Voltage
Hi=10V, Low=0V
THD
Full Load, 115VAC
8% max.
Full Load, 230VAC
15% max.
Full Load, 277VAC
17% max.
AC Current
115VAC
1.2A max.
230VAC
0.6A max.
Input/Output Isolation
3.75kVAC / 1minute
Input/Case Isolation
1.8kVAC / 1minute
Output/Case Isolation
0.5kVAC / 1minute
Leakage Current
230VAC
<0.75mA
Inrush Current
230VAC
50A
(Class C Circuit Breaker is recommended)
Voltage Tolerance
-1% to 5%
Current Tolerance
±5%
Start-up Time (@ Full Load)
230VAC
2s
Ripple & Noise
142V Version
1000mV max.
(@20MHz bandwidth)
71V Version
500mV max.
Over Voltage
110 - 140% Rated Voltage
Shutdown Mode
Short Circuit Protection
Hiccup Mode
Over Temperature Protection
100°C ±10°C
Operation Temperature
without derating
-30°C to +55°C (see graph)
Operation Humidity
20%-90% RH Non-Condensing
Storage Temperature
-40°C to +80°C
Storage Humidity
10%-95% RH
Vibration
10-500Hz, 2G, 60 Min. along X, Y and Z
IP Rating
IP67
Safety Standards
UL/cUL LED Lighting Safety
UL8750
CE LVD Directive, Safety
EN61347-2-13
CB
Report: 1103631 001
IEC61347-2-13
continued on next page
LIGHTLINE
AC/DC-Converter
with 5 year Warranty
100 Watt
Single
Output
RoHS
2011/65/EU
6/6
E340696
UL 8750 Certified
EN 61347 Certified
RACD100-A
Derating-Graph
(Ambient Temperature)
Load
100%
80%
100V
230V
60%
40%
20%
-30 -10 10 30 50 70
55
Ambient Temperature (°C)
Refer to Application Notes
L-62
REV: 0/2015