English
Language : 

RAC30-S-D-TA Datasheet, PDF (1/2 Pages) Recom International Power – 30 Watt Single/Dual/ Double & Triple Output
Features
Regulated
Converters
● AC-DC Power Supply
● 30 Watt PCB Mount Package
● Universal Input Voltage Range
● 3000VAC Isolation
● Low Output Ripple and Noise
● Short Circuit Protected
● Triple Output with Independent Outputs
● UL Certified, CE Marked
Description
Compact UL certified switching AC/DC power module for PCB, screw-
terminal connection or DIN-rail mounting.
Selection Guide
Part
Number
RAC30-3.3SA
Input
Range
(VAC)
90-264
Output
Voltage
(VDC)
3.3
Output
Current
(mA)
6000
Efficiency
(%)
75
Max.
Capacitive
Load
80000µF
RAC30-05SA
90-264
5
6000
79
70000µF
RAC30-12SA
90-264
12
2500
82
14000µF
RAC30-15SA
90-264
15
2000
82
11000µF
RAC30-24SA
90-264
24
1250
82
5900µF
RAC30-05DA
90-264
±5
±3000
79
±50000µF
RAC30-12DA
90-264
±12
±1250
82
±14000µF
RAC30-15DA
90-264
±15
±1000
80
±10000µF
RAC30-0512DA
90-264
5/12
3000/1250
79 13200/±6400µF
RAC30-0512TA
90-264
5/±12
3000/±630
79 15000/±5400µF
RAC30-0515TA
90-264
5/±15
3000/±500
78 10000/3200µF
*add suffix “-E” for extended temperature range, e.g. RAC30-05SA-E
*add suffix "-ST” for screw terminal module e.g. RAC30-05DA-ST, RAC30-0512TA-E-ST
Specifications (typical at 25°C and after warm up time unless otherwise specified )
Input Voltage Range
90-264VAC or 120-370VDC
Rated Power
30 Watts max.
Input Frequency Range (for AC Input)
47-440Hz
Input Current (full load)
115VAC/230VAC
520mA/ 320mA max.
No Load Power Consumption
115VAC/230VAC
2.58W max.
Inrush Current (<2ms)
115VAC
10A max. (-E = 23A max.)
230VAC
20A max. (-E = 46A max.)
Leakage Current
0.75mA max.
Output Voltage Accuracy (Full load)
Line Voltage Regul. (low line, high line at full load) (2) Single, Dual
±2%
±1% typ.
Double, Triple
±1%/±5% typ.
Load Voltage Regulation (5% to 100% full load) Single, Dual
±1%, ±3%typ.
Double, Triple
±2%/±6% typ.
Minimum Load
Single 3.3V: 5%/ 5V: 8%/ 12V, 15V, 24V: 2%
Dual
±5V: 2%/ ±12V: 3%/ ±15V: 1%
Double, Triple
20%
Output Ripple and Noise (20MHz limited)
Noise
0.5% Vout + 50mVp-p max.
Ripple
<0.2% Vout + 40mVp-p max.
Operating Frequency
100kHz typ.
Efficiency at Full Load
see table
RMS Isolation Voltage (input to output)
3kVAC min.
Temperature Coefficient
±0.02%/°C typ.
Isolation Resistance
100 MΩ max.
Short Circuit Protection
Continuous, Automatic restart
continued on next page
www.recom-power.com
REV: 0/2015
POWERLINE
AC/DC-Converter
with 3 year Warranty
30 Watt
Single/Dual/
Double &
Triple Output
RoHS
2011/65/EU
6/6
E196683
UL-60950-1 Certified
RAC30-A
Derating-Graph
(Ambient Temperature)
125
E-Version
100
75
Natural Convection
50
25
0
-40 -25 -10 0
60 70 80 90
50
Ambient Temperature Range (°C)
Refer to Application Notes
PA-49