English
Language : 

RAC05-S-DC Datasheet, PDF (1/3 Pages) Recom International Power – 5 Watt Single / Dual Output
Features
Regulated
Converters
● Universal Input 80-264VAC
● High efficiency up to 77%
● Isolated Output 3kVAC / 1 min
● Short Circuit Protection
● Meet EN55022 Class B
● Low Standby Power Consumption
POWERLINE
AC/DC-Converter
with 3 year Warranty
Description
Selection Guide
Part
Number
Input
Voltage
(VAC)
RAC05-3.3SC*
80-264
RAC05-05SC*
80-264
RAC05-09SC*
80-264
RAC05-12SC*
80-264
RAC05-15SC*
80-264
RAC05-24SC*
80-264
RAC05-05DC*
80-264
RAC05-12DC*
80-264
RAC05-15DC*
80-264
* add suffix /W for wired version
Compact, low cost, high efficiency, universal input switching AC/DC
power module for PCB or wired mounting with single or dual outputs.
CE marked and UL/cUL certified.
Output
Voltage
(VDC)
3.3
5
9
12
15
24
±5
±12
±15
Output
Current
(max.)
1250
1000
556
420
340
210
±500
±210
±170
Efficiency
(Typ.)
70
73
75
76
76
77
73
76
76
Max.
Capacitive
Load (1+2)
12000µF
6800µF
2500µF
1500µF
750µF
330µF
±3000µF
±560µF
±220µF
Specifications (measured at TA 25°C, full load after warm-up)
Input Voltage Range (with derating)
80-264VAC or 115-370VDC
Rated Power
5 Watts max.
Input Frequency (for AC Input)
47-440Hz
Input Current (Full Load)
115VAC / 230VAC
110mA / 70mA typ.
Inrush Current (<2ms)
115VAC / 230VAC
30A / 60A max.
Minimum Load (Specifications valid with 5% min.)
0%
No Load Power Consumption
0.25W max.
Recommended External Input Fuse
1.5A / Slow Blow Type
Output Voltage Accuracy (Full Load)
115VAC / 230VAC
±2% max.
Line Voltage Regulation (Full Load)
LL-HL
±0.3% typ.
Load Voltage Regulation
5-100% Load
±0.5% typ.
Output Ripple&Noise @115/230VAC
3.3V
120mV max.
(20MHz limited with 100nF across output) All Others
150mV max.
Switching Frequency (Full Load)
132kHz typ.
Efficiency (Full Load)
see Selection Guide
Hold-Up Time (Full Load)
115VAC
10ms typ.
Leakage Current
0.85mA max.
Isolation Voltage
Input-Output
3kVAC / 1minute
Isolation Capacitance
Input-Output
1000pF typ.
Isolation Resistance
Input-Output
1G Ω min.
Short Circuit Protection
Hiccup, Automatic Restart
Overvoltage Protection
3.3V
4.8 V- 5.4V
(of Nominal Output Voltage)
All Others
110% - 135%
Over Voltage Category
OVC II
Operating Temperature Range (3)
-25°C to +55°C (without Derating)
(Natural Convection)
-25°C to +75°C (with Derating)
Storage Temperature Range
-40°C to +100°C
Case Material
UL94V-0 Black Plastic
continued on the next page
5 Watt
Single / Dual
Output
RoHS
2011/65/EU
6/6
E224736
EN-60950-1 Certified
UL-60950-1 Certified
RAC05-C
Derating-Graph
(Ambient Temperature)
100
80 Safe Operating Area
60
40
30
0
-25 0 20 40 60 80 100
55 75
Ambient Temperature Range (°C)
Refer to Application Notes
PA-30
REV: 0/2015