Features
Regulated
Converters
● Ultracompact Low Profile AC-DC Power Supply
● Ultra-low 30mW Standby Power Consumption
● 1 Watt or 2 Watt PCB Mount Package
● Extra Wide Input Voltage Range (80~264VAC)
● Class II Power Supply with 3kVAC Isolation
● -25°C to +85°C Operating Temp
● Low Output Ripple
● Short Circuit Protected Outputs
● EN, UL and CE Certified
Description
The RAC01-SC and RAC02-SC series are ultra-compact universal input
AC/DC power modules for PCB mounting. They feature high efficiency, low
standby power, high operating temperature, soft start and short-circuit
protection as well as a built-in EMC Class B filter. Output voltages range from
3.3VDC to 24VDC.
Selection Guide
Part
Number
RAC01-3.3SC
RAC02-3.3SC
RAC01-05SC
RAC02-05SC
RAC01-09SC
RAC02-09SC
RAC01-12SC
RAC02-12SC
RAC01-15SC
RAC02-15SC
RAC01-24SC
RAC02-24SC
Input
Range
(VAC)
80-264
80-264
80-264
80-264
80-264
80-264
Output
Voltage
(VDC)
3.3
5
9
12
15
24
Output
Current
(mA)
300
600
200
400
111
222
83
167
67
133
42
83
Efficiency Max
typ. Capacitive
(%)
Load (1+2)
65
2200µF
66
2700µF
68
1600µF
70
2000µF
70
470µF
72
560µF
72
180µF
74
200µF
72
180µF
74
200µF
73
68µF
77
68µF
Specifications (measured at TA 25°C, full load after warm-up)
Input Voltage Range (with derating)
80-264VAC or 115-370VDC
Rated Power
1 or 2 Watts max.
Input Frequency Range (for AC Input)
47-63Hz
Input Current (full load)
RAC01 (115/230VAC)
34mA/23mA max.
RAC02 (115/230VAC)
55mA/36mA max.
No Load Power Consumption
@115VAC
30mW typ.
@230VAC
80mW typ.
Inrush Current (<0.5ms)
30/60A max.
Leakage Current
0.25mA max.
Output Voltage Tolerance (combined Tolerance, Line Reg and Load Reg at full load)
±5% max.
Line Voltage Regulation
low line, high line at full load
±2% max.
Load Voltage Regulation
10% to 100% full load
±6% max.
Output Ripple (20MHz BW limited)
3.3V Output
<150mVrms
All others
<100mVrms
Operating Frequency (full load)
30kHz typ.
Minimum Load = 0%
specifications valid for 10% minimum load only
RMS Isolation Voltage (input to output)
3kVAC / 1 minute
Isolation Resistance
1 GΩ min.
Short Circuit Protection
Hiccup, Automatic Restart
Over Voltage Category
OVC II
Operating Temperature Range (3)
(1W, natural convection, no derating) -25°C to +80°C
(2W natural convection, no derating) -25°C to +75°C
(natural convection, with derating)
-25°C to +85°C
Storage Temperature Range
-40°C to +100°C
Humidity
non-condensing
95% RH max
Case Material
Plastic Case, Silicone potting material (UL94V-0)
continued on next page
PA-2
REV: 0/2015
POWERLINE
AC/DC-Converter
with 3 year Warranty
1 - 2 Watt
Single
Output
RoHS
2011/65/EU
6/6
E224736
EN-60950-1 Certified
UL-60950-1 Certified
RAC01-C
RAC02-C
Derating-Graph
(Ambient Temperature)
125
Natural Convection
100
2W 1W
75
50
25
0
-25
0 50 60 75808590 100
Ambient Temperature Range (°C)
Refer to Application Notes
www.recom-power.com