English
Language : 

RAA Datasheet, PDF (1/2 Pages) Recom International Power – ECONOLINE - DC/DC - CONVERTER
Features
Unregulated
Converters
● Dual In-Line Package
● 1kVDC Isolation
● Internal Filtering
● No External Components Required
● 100% Burned In
● UL94V-0 Package Material
● Low Noise
● Efficiency to 87%
Selection Guide
Part
Number
Input
Voltage
DIP Package
(VDC)
RAA-0505S
5
RAA-0512S
5
RAA-0515S
5
RAA-1205S
12
RAA-1212S
12
RAA-1215S
12
RAA-2405S
24
RAA-2412S
24
RAA-2415S
24
RAA-0505D
5
RAA-0512D
5
RAA-0515D
5
RAA-1205D
12
RAA-1212D
12
RAA-1215D
12
RAA-2405D
24
RAA-2412D
24
RAA-2415D
24
Output
Voltage
(VDC)
5
12
15
5
12
15
5
12
15
±5
±12
±15
±5
±12
±15
±5
±12
±15
Output
Current
(mA)
1000
417
333
1000
417
333
1000
417
333
±500
±208
±167
±500
±208
±167
±500
±208
±167
Input Current
Full Load No Load
(mA)
1250 80
1150 80
1150 80
496 40
479 40
479 40
261 20
245 20
239 20
1250 80
1150 80
1150 80
496 40
479 40
479 40
261 20
245 20
239 20
Efficiency
(%)
80
87
87
84
87
87
83
85
87
80
87
87
84
87
87
83
85
87
Specifications (Core Operating Area)
Voltage Setpoint Accuracy
±3% max.
Temperature Coefficient
±0.03%/°C
Ripple and Noise (20MHz BW)
100mVp-p max.
Line Regulation (for 1% change in input voltage)
±1.2% max.
Load Regulation (for output load current change from 20% to 100%)
±3% max.
Short Circuit Protection
Short Term
Input Voltage Range
±10% min.
Efficiency
79% - 91%
Isolation Voltage
Rated Working Voltage
(tested for 1 second)
(long term isolation)
1.000VDC min.
see Application Notes
Isolation Resistance
10 GΩ min.
Switching Frequency
60kHz min.
Isolation Capacitance
80pF max.
Operating Temperature Range (free air convection)
-25°C to +70°C (see Graph)
Storage Temperature
-55°C to +100°C
Relative Humidity
MSL Level 1
95% RH
Case Material
Non-Conductive Plastic
Package Weight
} MTBF (+25°C) Detailed Information see
using MIL-HDBK 217F
(+70°C) Application Notes chapter "MTBF" using MIL-HDBK 217F
19.2g
1800 x 103hours
1440 x 103hours
108
April-2005
ECONOLINE
DC/DC-Converter
RAA
Series
5 Watt
25.00 x 23.50mm
Single &
Dual Output
Derating-Graph
(Ambient Temperature)
120
100
80
60
Safe Operating Area
40
20
0
-25 0 25 50 75 100
70
Operating Temperature (°C)
www.recom-international.com