English
Language : 

RAA-0505S_06 Datasheet, PDF (1/2 Pages) Recom International Power – 5 Watt 25.00 x 23.50mm Single & Dual Output
Features
Unregulated
Converters
● Dual In-Line Package
● 1kVDC Isolation
● Internal Filtering
● No External Components Required
● 100% Burned In
● UL94V-0 Package Material
● Low Noise
● Efficiency to 87%
Selection Guide
Part
Number
Input
Voltage
DIP Package
(VDC)
RAA-0505S
5
RAA-0512S
5
RAA-0515S
5
RAA-1205S
12
RAA-1212S
12
RAA-1215S
12
RAA-2405S
24
RAA-2412S
24
RAA-2415S
24
RAA-0505D
5
RAA-0512D
5
RAA-0515D
5
RAA-1205D
12
RAA-1212D
12
RAA-1215D
12
RAA-2405D
24
RAA-2412D
24
RAA-2415D
24
Output
Voltage
(VDC)
5
12
15
5
12
15
5
12
15
±5
±12
±15
±5
±12
±15
±5
±12
±15
Output
Current
mA)
1000
417
333
1000
417
333
1000
417
333
±500
±208
±167
±500
±208
±167
±500
±208
±167
Input Current
Full Load No Load
(mA)
1250
80
1150
80
1150
80
496
40
479
40
479
40
261
20
245
20
239
20
1250
80
1150
80
1150
80
496
40
479
40
479
40
261
20
245
20
239
20
Efficiency
(%)
80
87
87
84
87
87
83
85
87
80
87
87
84
87
87
83
85
87
Specifications (Core Operating Area)
Voltage Setpoint Accuracy
±3% max.
Temperature Coefficient
±0.03%/°C
Ripple and Noise (20MHz BW)
100mVp-p max.
Line Regulation (for 1% change in input voltage)
±1.2% max.
Load Regulation (for output load current change from 20% to 100%)
±3% max.
Short Circuit Protection
1 Second
Input Voltage Range
±10% min.
Efficiency
See Selection Guide
Isolation Voltage
Rated Working Voltage
(tested for 1 second)
(long term isolation)
1000VDC min.
see Application Notes
Isolation Resistance
10 GΩ min.
Switching Frequency
50kHz typ.
Isolation Capacitance
80pF max.
Operating Temperature Range (free air convection)
-25°C to +70°C (see Graph)
Storage Temperature
-55°C to +100°C
Relative Humidity
95% RH
Case Material
Non-Conductive Plastic
Package Weight
} MTBF (+25°C) Detailed Information see
(+70°C) Application Notes chapter "MTBF"
using MIL-HDBK 217F
using MIL-HDBK 217F
19.2g
1415 x 103hours
243 x 103hours
120
July-2006
ECONOLINE
DC/DC-Converter
RAA
Series
5 Watt
25.00 x 23.50mm
Single & Dual
Output
Derating-Graph
(Ambient Temperature)
120
100
80
60
Safe Operating Area
40
20
0
-25 0 25 50 75 100
70
Operating Temperature (°C)
www.recom-international.com