English
Language : 

R1SE_15 Datasheet, PDF (1/2 Pages) Recom International Power – 1 Watt SMD Isolated Single Output
Features
Unregulated
Converter
● 1 : 1 Input Range
● SMD Package
● Efficiency up to 75%
● 1kVDC Isolation
● Operating Temperature from -40°C to +85°C
● UL Certified
Selection Guide
Part
Number
SMD
Input
Voltage
(VDC)
R1SE**-0505*
5
*add suffix -R for tape & reel packing
Output
Voltage
(VDC)
5
Case and Pinning Options
** without marking denotes 5 pins out of 8 fitted
with marking 8 denotes 8 pins out of 8 fitted
Output
Current
(mA)
200
Efficiency
typ.
(%)
75
Specifications (measured at TA = 25°C, nominal input voltage full load and after warm up)
Input Voltage Range
±10% max.
Voltage set Accuracy
100% Load/nominal Vin
-2% typ. / ±5% max.
Line Regulation
Low Line to High Line @ max. Load
1.2% typ.
Load Regulation
(10% to 100% Load)
10% typ. / 15% max.
Ripple & Noise @ 20MHz BW
68mVp-p typ. / 100mVp-p max.
Efficiency
100% Load
70% min. / 75% max.
Operating Temperature
-40°C to + 85°C
Storage Temperature
-55°C to +125°C
Isolation Test Voltage
(tested for 1 second)
1000VDC
(rated for 1 minute***)
500VAC / 60Hz
Isolation Capacitance
75pF max.
Isolation Resistance
Viso = 500V
10 GΩ min.
Humidity
95% max.
Operating Frequency
Vin (nom.)
20kHz min. / 70 kHz max.
Short-Circuit Protection
1 Second
Weight
1.0g
MTBF
Using MIL-HDBK 217F (+90°C)
172 x 10³ hours
Using MIL-HDBK 217F (+25°C)
1022 x 10³ hours
Detailed Information see Application Notes chapter „MTBF“
Certification
UL General Safety
Report: E358085-A2
UL60950-1
***Any data referred to in this datasheet are of indicative nature and based on our practical experience only. For further details, please refer
to our Application Notes.
Tolerance Envelopes
Tolerance Envelopes
+10%
+5%
VNOM
Typical Load Line
+5%
-2%
-5%
E-30
10%
50%
100%
+Vout and -Vout load current (%)
REV: 0/2015
ECONOLINE
DC/DC-Converter
with 3 year Warranty
1 Watt SMD
Isolated
Single Output
RoHS
2011/65/EU
6/6
E358085
UL-60950-1 Certified
R1SE
Derating-Graph
(Ambient Temperature)
100
80
60 Safe Operating Area
40
20
0
-40 0 50 100 150
85
Operating Temperature °C
Refer to Application Notes
www.recom-power.com