English
Language : 

PFM4914XB6M24D0YZZ Datasheet, PDF (1/24 Pages) Vicor Corporation – Versatile thermal management
VIA PFM™
PFM4914xB6M24D0yzz
®
C
US
S
C NRTL US
Isolated AC-DC Converter with PFC
Features & Benefits
• Universal input (85 to 264 VAC)
• 24 VOUT, regulated, isolated
• 400 W maximum power
• High efficiency
• Built-in EMI filtering
• Chassis mount or board mount packaging options
• Always-on, self-protecting converter control architecture
• SELV Output
• Two temperature grades including operation to -40°C
• Robust package
• Versatile thermal management
• Safe and reliable secondary-side energy storage
• High MTBF
• 127 W/cubic inch power density
• 4914 package
• External rectification and transient protection required
Typical Applications
• Small cell base stations
• Telecom switching equipment
• LED lighting
• Test and measurement equipment
• 200 - 400 W Industrial power systems
• Office equipment
Part Ordering Information
Product Description
The VIA PFM is a highly advanced 400 W AC-DC converter
operating from a rectified universal AC input which delivers an
isolated and regulated Safety Extra Low Voltage (SELV) 24 V
secondary output.
This unique, ultra-low profile module incorporates AC-DC
conversion, integrated filtering and transient surge protection
in a chassis mount or PCB mount form factor.
The VIA PFM enables a versatile two-sided thermal strategy
which greatly simplifies thermal design challenges.
When combined with downstream Vicor DC-DC conversion
components and regulators, the VIA PFM allows the Power
Design Engineer to employ a simple, low-profile design which
will differentiate his end-system without compromising on
cost or performance metrics.
Size:
4.91 x 1.40 x .37 in
124.8 x 35.5 x 9.3 mm
Product
Function
Package Package
Length Width
Package
Type
Input
Voltage
Range
Ratio
Output
Voltage
(Range)
Max
Output
Current
Product Grade
Option Field
P FM4 9 1 4
x
B6
PFM =
Power Factor
Module
Length in Width in B = Board VIA
Inches x 10 Inches x 10 V = Chassis VIA
M
24D0
y
z
z
Internal Reference
C = -20 to 100°C
T = -40 to 100°C
00 = Chassis/Always On
04 = Short Pin/Always On
08 = Long Pin/Always On
VIA PFM™
Page 1 of 24
Rev 1.3
07/2015
vicorpower.com
800 927.9474